Stoelting SU412 Скачать руководство пользователя страница 32

Owner’s Manual #513625 

28 

SU412 Model Machines

Error Code 5 - Freezing Cylinder Sensor

 

The Freezing Cylinder Sensor Error (E5) indicates 
a failure of the barrel sensor or if the sensor is 
out of range. If the control panel displays an E5, 
place the Freezing Cylinder Off-On switch in the 
Off position and back in the On position. If the 
error persists, contact your Authorized Stoelting 
Distributor for further assistance.

NOTE

When the machine encounters a Freezing Cylinder 
Sensor Error, the machine will continue to run using 
preset timers. This mode will allow the operator to 
continue serving product until the machine can be 
serviced.

Error Code 6 - Hopper Sensor (single hopper machines)

 

The Hopper Sensor Error (E6) will not occur on 
the SU412 machine.

Error Code 7 - Drive Motor

 

If the control panel displays a Drive Motor Error 
(E7), the control does not sense the drive motor. 
Place the Freezing Cylinder Off-On switch in the 
Off position and back in the On position. If the 
error persists, contact your Authorized Stoelting 
Distributor for further assistance.

Error Code 8 - Cab Sensor

 

A Cab Sensor Error (E8) indicates a cabinet 
temperature sensor failure or. This error will 
also appear if the sensor is out of range. If the 
control panel displays an E8, place the Freezing 
Cylinder Off-On switch in the Off position and back 
in the On position. If the error persists, contact 
your Authorized Stoelting Distributor for further 
assistance.

Error Code 9 - High Pressure Cutout

 

High Pressure Cutout Errors (E9) are usually 
caused by a dirty or ineffi cient condenser.

 

In air cooled condenser models, check for proper 
air clearance around the machine.

 

In water cooled condenser models check for 
proper water fl ow.

 

If the error persists, contact your Authorized 
Stoelting Distributor for further assistance.

Error Code 10 - Auxiliary Sensor

 

An Auxiliary Temperature Sensor Error (E10) 
occurs if the temperature sensor on the control 
board fails. Place the Freezing Cylinder Off-
On switch in the Off position and back in the 
On position. If the error persists, contact your 
Authorized Stoelting Distributor for further 
assistance.

Error Code 11 - Low Temperature

 

The Low Temperature Error (E11) occurs when 
there is a very low temperature in the freezing 
cylinder. Although the machine will not shut down, 
the active freezing cycle will immediately end. This 
error usually occurs when the machine continues 
to run in a low mix condition or if the machine 
runs out of mix. The product towards the front of 
the freezing cylinder tends to freeze solid. When 
the temperature on the freezing cylinder lowers 
to the preset value, the IntelliTec™ control will 
display an E11.

ALTERNATING FLASHING CONTROL PANEL LIGHTS

 

The display panel lights will fl ash in an alternating 
sequence under any error codes. Clear the error 
and place the Freezing Cylinder Off-On switch in 
the Off position and back in the On position.

Содержание SU412

Страница 1: ...Model SU412 OPERATORS MANUAL Manual No 513625 Rev 4...

Страница 2: ......

Страница 3: ...built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or q...

Страница 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Страница 5: ...ting Controls and Indicators 7 3 3 Emptying the Freezing Cylinder 9 3 4 Disassembly of Machine Parts 9 A Remove Blender 9 B Remove Front Door 10 C Remove Auger 10 D Pump Hose Disassembly 10 3 5 Cleani...

Страница 6: ...rrun Adjustment 22 4 9 Mix Pump Hose Reposition 23 4 10 Mix Pump Hose Replacement 23 4 11 Cab Temperature Adjustment 24 4 12 Drive Belt Tension Adjustment 24 4 13 Condenser Cleaning Air Cooled Freezer...

Страница 7: ...machine It is equipped with fully automatic controls to provide a uniform product This manual is designed to assistqualifiedservicepersonnelandoperatorswithinstal lation operationandmaintenanceoftheS...

Страница 8: ...VAC 60Hz circuit ampacity 19A minimum overcurrent protection device 30A maximum Compressor 11 000 Btu hr Scroll Compressor Drive Motor 3 4 hp Air Flow Air cooled units require 3 7 6 cm air space on b...

Страница 9: ...ise the carrier within 10 days and request inspection The customer must place a claim for damages and or short ages in shipment with the carrier Stoelting Inc cannot make any claims against the carrie...

Страница 10: ...the left side of the mix line manifold using a small hose clamp Be careful not to twist the mix hose 7 Turn the pump on 8 Allow the remaining 6 15cm of tubing to feed through pump until the hose adap...

Страница 11: ...em BCS withThree Bags optional kit The position of the three bags in the mix container is im portant The bag that is connected nearest the outlet of the manifold drains last and should be placed at th...

Страница 12: ...f the tubing to a manifold adapter Securewithalargehose clamp 3 Push the manifold adapter with spring and valve into the left port nearest the manifold outlet of the mix inlet manifold and secure with...

Страница 13: ...perating control Refer to Figure 3 1 for the location of the operating controls on the machine For the information regarding error codes displayedonthecontrolpanel refertothetroubleshooting section of...

Страница 14: ...he freezing cycle stops and the drive motor starts A CLEAN message will display on the LCD screen along with a 5 minute countdown timer If the button is pressed again the timer resets To exit the CLEA...

Страница 15: ...ld the blender shaft and turn the agitator counterclockwise b Loosenknobsholdingtheblendersplashshield assembly in place and remove the assembly 3 Remove the knobs on the front door Remove the blender...

Страница 16: ...r bleed valve by unscrewing the knob while holding the valve stem from behind Remove the compression spring and push the air bleed valve through the rear of the front door 4 Removethespigotthroughtheb...

Страница 17: ...he steel A Clean the rear seal surface at the back of the freezing cylinder B Using sanitizing solution and the large barrel brush provided sanitize the freezing cylinder by dipping the brush in the s...

Страница 18: ...with the manufacturer s instructions CAUTION Risk of Product Damage Avoid prolonged contact of sanitizer with machine parts Sanitizer may cause corrosion of stainless steel parts if there is prolonge...

Страница 19: ...again will change the value to 0 13 After entering 8 0 press SET to save this value The LCD will read CutOut Set OK 14 Press the SEL button The LCD will read CutOut amps 8 0 15 Press the SEL button t...

Страница 20: ...gerated cab E Place the mix pump switch in the ON position F Place a container under the spigot and open the spigot to allow the mix to flush out about 8 ounces 0 23 liters of sanitizing solution and...

Страница 21: ...he mix intake or pickup The right sideofthehoseisthemixdischarge Mixisdrawn up the pickup side of the hose and transferred through the discharge side to the machine Fig 3 10 B Air Operation The air co...

Страница 22: ...apter and bag adapter if applicable as an assembly from the mix container C Completely disassemble the hose assembly and the check valve Fig 3 11 Place hoses tee checkvalveassembly andpickuphoseadapte...

Страница 23: ...use When set all buttons on the control panel are disabled Follow the instructions below to lock the control panel A Press and hold the PUSH TO FREEZE button for at least 5 seconds B While still holdi...

Страница 24: ...Suction line temperature on the freezing cylinder and drive motor amps are available on the same screen to assist with setup and troubleshooting Aux Temp F This reading provides the ambient temperatu...

Страница 25: ...reat which the freezing cycle starts This value along with the CutOut value determines the range of temperatures or temperature window of the product Decreasing the temperature decreases the temperatu...

Страница 26: ...Hopper or 2 Hopper is selected for the Refriger setting Cab Off will not be shown on the IntelliTec menu Cab On If the Refriger value is set to Cabinet and the temperaturesensorinthecabinetfails thiss...

Страница 27: ...ollow the steps below to reposition the hose A Run cleaning solution through pump B Turn the pump off and relieve any pressure by opening the spigot C Grasp the pickup hose end of the mix pump hose wi...

Страница 28: ...ress and hold SEL button for 8 seconds While still holding the SEL button press the up arrow button The LCD Screen will read Display B Release both buttons C Press the left arrow button three 3 times...

Страница 29: ...for any unusual noise or condition and repair immediately B Monthly checks 1 Check drive belts for wear and tighten belts if necessary Refer to section 4 12 2 Check the condenser filter for dirt Refe...

Страница 30: ...Owner s Manual 513625 26 SU412 Model Machines...

Страница 31: ...r or from product breakdown Another common cause results from a restriction preventing mix fromenteringthefreezingcylinder Checkthemix in the hopper If the level mix is low add mix If there is a possi...

Страница 32: ...If the error persists contact your Authorized Stoelting Distributor for further assistance Error Code 9 High Pressure Cutout High Pressure Cutout Errors E9 are usually caused by a dirty or inefficien...

Страница 33: ...See Section 3 2 Low overrun setting 2 Raise overrun See Section 4 3 Low pump pressure 3 Check pump pressure 4 Large air pocket in barrel 4 Purge air from barrel 5 Auger turning counter clockwise 5 Ch...

Страница 34: ...case turn the pump off Draw 2 3 pints to reduce system pressure to zero Turn pump on Purge remaining air in mix bag and pick up hose Important before connecting the pick up hose to the mix bag remove...

Страница 35: ...iately disassemble and clean pump 1 Mix pump hose service life is exceeded 1 Remove mix pump hose Disconnect pump from power source Remove mix pump cover clamp Clean the rollers a small amount of soap...

Страница 36: ...Owner s Manual 513625 32 SU412 Model Machines...

Страница 37: ...Caution Rotating Blades 1 324200 Decal High Pressure Cut Out 1 324208 Decal Attention Refrigerant Leak Check 1 324346 Decal Caution Hazardous Moving Parts 1 324478 Decal Electrical Box L H 1 324509 D...

Страница 38: ...82019 Knob Front Door Black 4 624520 O Ring Air Bleed Valve Black 2 624614 O Ring Spigot Black 2 624678 O Ring Rear Seal Black 2 625314 O Ring Front Door Black 1 667868 Seal Rear Auger Orange 1 694200...

Страница 39: ...lender Agitator Collar SU412 1 417010 Grid Drip Tray Metal 1 521026 Blender Agitator SU412 1 674147 Blender Shaft 5 SU412 1 674174 Blender Shaft 7 6 SU412 1 674183 Blender Shaft 6 6 SU412 1 681518 Swi...

Страница 40: ...Cone Cab Check Valve 1 696152 Clip Lock Check Valve Cab 3 756067 Tubing 1 4 ID Clear Air Line 25 Increments Per Inch 13 756079 Tubing 3 8 ID Clear Mix Line 25 Increments Per Inch 24 756088 Tubing 1 2...

Страница 41: ...se obligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affected equipment b gives Stoelting pro...

Страница 42: ...ed to hoses piping or electrical equipment e Labor and travel charges due to return trips or waiting if the Authorized Stoelting Provider is prevented from promptly starting service work upon arrival...

Отзывы: