Операторы могут бесплатно скачать руководство по эксплуатации VAUPEL 3200 K1 с нашего веб-сайта. Это удобное пособие поможет вам максимально эффективно использовать данное оборудование. Скачать руководство можно на manualshive.com.
OPERATING MANUAL 3200 K1 V4.4/20-EN
Page | 1
Disinfectant
pressure cup gun 3200 K1
Art. no.: 32304, 32305
Страница 1: ...OPERATING MANUAL 3200 K1 V4 4 20 EN Page 1 Disinfectant pressure cup gun 3200 K1 Art no 32304 32305 ...
Страница 2: ... this operating manual with the pressure cup gun General notice This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5 7 Ma...
Страница 3: ... cup gun is a compressed air operated quality tool for professional use It is suitable for processing liquid media in the form of loose containers 4 Features The effectiveness of the 3200 K1 pressure cup gun is based on overpressure For this purpose pressure is built up in the pressure container by means of an air duct integrated in the gun body This conveys the material present in the pressure co...
Страница 4: ...nly use original spare parts The maximum working pressure must not be exceeded see point 1 Technical data The working pressure must be adjusted via a filter pressure reducer Only use compressed air as energy source The compressed air connection may only be made via quick coupling When working with the pressure cup gun wear the necessary protective clothing protective goggles work gloves ear pro te...
Страница 5: ...ng the intake pressure optional Distance between hand spray nozzle and object Angular position of the hand spray nozzle to the object End of work Vent the pressure container by turning the pressure container counterclockwise Disconnect the device from the compressed air supply after each use Empty the pressure container Clean the device and the hoses as de scribed in point 7 Attention Never operat...
Страница 6: ...ve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several times Material exits the spray nozzle even though the trigger is in its initial posi tion Possible cause Nozzle needle is jammed dirty Solution Clean the nozzle needle apply oil to the nozzle needle and or slightly re duce the pressure on the nozzle needle seal using a 9mm wren...
Страница 7: ...rvice your sales representative is at your side or contact the follow ing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from the original We assume no liability for printing errors ...
Страница 8: ...rdance with the above EC Di rectives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging t...
Страница 9: ...60 4100 364 O ring 5 x 1 mm 17 30 1421 012 Needle gland 18 60 4100 366 O ring 8 x 2 5 mm 19 30 2122 005 Nozzle head 20 20 1413 001 Quick coupling 21 siehe Zubehörliste Cavity spray hose accessory 22 83313 O ring 15 x 2 mm 23 Adapter 3000 25 O ring 33 x 2 mm 26 10 2112 006 Container lid with 27 60 4100 344 U cup 12 x 18 x 4 5 x 1 6 28 60 4100 060 O ring 84 x 4 mm 29 83309 Fixing screw 30 10 4102 00...