OPERATING MANUAL 3200 K1 V4.4/20-EN
Page | 5
6.
Installation / end of work
Preparing the gun for the first start-up:
Screw in the compressed air connection
and tighten it firmly using a 13 mm open-end wrench or ring spanner, if
necessary glue it in place.
With optional pressure regulator instead of air volume regulation
: Screw the
pressure gauge included in the extent of delivery into the pressure regulating
device, if necessary glue it in place.
Start-up: Unscrew the pressure container and fill the medium into the con-
tainer. Then hand-tighten the gun with the container cover onto the pressure
container. Do not use any tools for this! Plug the connection nipple of the hose
(type 3900 or 3901) onto the quick coupling and let it engage. Connect the gun
to the compressed air supply via the quick coupling of the air connection. By
pressing the trigger you put the pressure cup gun into operation.
The spray pattern can be influenced by the following factors:
•
Material quantity via stop screw/nozzle needle
•
Adjusting the intake pressure (optional)
•
Distance between hand spray nozzle and object
Angular position of the hand spray nozzle to the object
End of work:
Vent the pressure container by turning the pressure container
counterclockwise.
Disconnect the device from the compressed air supply after
each use. Empty the pressure container. Clean the device and the hoses as de-
scribed in point 7.
Attention:
Never operate the trigger while the container is under pres-
sure but the pressure cup gun is not connected to the com-
pressed air source. This can push the medium into the air ducts
and render the pressure cup gun unusable!
7.
Maintenance and care
Clean the compressed air device after each use. Empty the pressure container
and blow out the pressure cup gun and the hoses by putting the device into
operation. If you want to clean the pressure cup gun with cleaning agent, we
recommend benzine or commercially available turpentine-based cleaning
agents..
Do not use aggressive cleaning media!
Following the maintenance in-
structions will ensure a long service life and trouble-free operation for this qual-
ity product.
Attention:
Pay attention to a proper disposal of the residues, which arise
during the maintenance and care.