Technical Problems / Alarm Code
ALARM
DESCRIPTION
ACTION
SOLUTIONS
Chamber probe
Chamber probe failure
Cooking stopped, automatic restore
Replace chamber probe. Contact the Stoddart service department
Core probe
Core probe error
Manual restore
Replace core probe. Contact the Stoddart service department
Motor safety
Motor Alarm
Cooking stopped, automatic re-arm
If continuous, contact the Stoddart service department
Inverter code :
Motor Inverter Alarm
Cooking stopped, automatic re-arm
Contact the Stoddart service department
Chamber safety
Chamber safety thermal.
Cooking stopped, manual re-arm
Check the safety thermostat (page 50).
Hi temp
Technical compartment
temperature too high.
Cooking stopped, automatic restore
Check oven's perimeter ventilation, the lower air filter (pag. 46) and
the correct functioning of the cooling fans of the components.
No water
No water for the
production of steam.
Cooking stopped, automatic restore.
Check water connection to oven. If problem persists contact the Stoddart
service department
No water flow
meter
Washing flowmeter
alarm
Washing is stopped
Check water connection to oven. If problem persists contact the Stoddart
service department
Communi cation
Main board
communication error
Cooking stopped
Switch off at main, if persists: Contact the Stoddart service department
Power failure
Electrical power failure
Cooking stopped
Press encoder button for 1 Second.
Probe 4
Humidity control system
probe 4 failure
Cooking stopped
Contact the Stoddart service department
Probe 5
Humidity control system
probe 5 failure
Cooking stopped