Installation
Three Phase Units:
• A terminal block for on-site connection, by a licensed electrician located inside the service compartment of the unit, indicated as:
- 3Ø + N + E
On-site Connection:
• The electrical supply must comply with the rating plate data
• Ensure that the machine is connected to a suitably rated power source
• Disconnection must be incorporated in the fi xed wiring in accordance with the wiring rules
• To connect the power, the unit has a terminal block supplied inside the service compartment
This unit must be installed in accordance with AS/NZS 60335.1
Some procedures in this manual require the power to the equipment to be turned off and isolated.
Turn the power OFF at the power point and unplug the power supply lead by the plug body. If the
power point is not readily accessible turn the equipment off at the isolation switch or the circuit
breaker in the switchboard. Attach a yellow “CAUTION-DO NOT OPERATE” tag. This must be
performed where relevant unless the procedures specify otherwise.
FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK.
WARNING
Single Phase Units:
• A terminal block for on-site connection, by a licensed electrician located inside the service compartment of the unit, indicated as:
- 1Ø + N + E
• Supplied and fi tted with an appropriately rated plug and lead
Notes:
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a
hazard. Please contact Stoddart for parts and we will advise how to do this in order to avoid any electrical hazard
• The power cable should be dry and/or isolated from moisture or water
PE
N5
N4
Yellow/Green: Earth
Neutral
L1
L3
L2
Phases
L1
N5
PE
AC 415V
3Ø + N + E
AC 230V
1Ø + N + E
L1
L2
L3
N4
N5
PE
1. Remove service compartment cover
2. Connect electrical wiring, following the below wiring diagram.
After connecting wires, use a multimeter to check:
• There is no electrical dispersion between the phases and the earth
• For electrical continuity between the external casing and the mains earth
3. Reinstall service compartment cover
4. Secure wiring cable by fastening the cable gland nut
Wiring
x3
The links provided must be in this configuration for
single phase.
Fan rotation does not need to be checked
Electric Model
KM0623WT
KM061WT
KM101WT
Weight
77 kg
92 kg
110 kg
Power (kW)
4.7 kW
415V 3Ø + N + E (3 x 7A)
230V 1Ø + N + E (1 x 21A)
6.9 kW
415V 3Ø + N + E (3 x 10A)
230V 1Ø + N + E (1 x 30A)
13.8 kW
415V 3Ø + N + E (3 x 20A)