Page 49
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
Cleaning and Maintenance
Water Filtration
1. Turn off water supply at the isolation tap
2. Remove the old filter cartridge (unscrew clockwise)
3. Before installing the replacement filter cartridge, mark the
installation date and the replacement date (no later than 6
months) on the filter’s rating plate. Diarise the replacement
date as a reminder
4. Install new filter cartridge (screw in anti-clockwise). To order
new cartridge see Page 62
5. Turn on the water supply
6. Flush/bleed the new cartridge by pressing the “Bleed Button”
for a minimum of 60 seconds (located on the top of the filter
head)
•
Filter to be changed a minimum of every 6 months, or more frequently in
areas with poor water quality
Old Cartridge
New Cartridge
BWT Filter Cartridge
Bleed Button
• Water filtration is critical to the performance of the oven. Users must establish a regular filter replacement schedule. Required
frequency will depend on the water quality and type of filtration system
• Filter change frequencies below are indicative minimums. If water quality is poor, the filter may need to be replaced more frequently
• Indicators that filters may require changing are:
- Surface corrosion present in the oven cavity. Contact Stoddart for advice
- Scale building up more frequently than normal
- Oven starving for water creating error messages
Reverse Osmosis Filter Cartridges
• A reverse osmosis filter is required in areas where the water has high chlorides or
other corrosive minerals present. Where appropriate, this system should have been
recommended by your supplier at the time of your oven purchase
• Filters 1, 2 and 4 to be changed a minimum of every 6 months, or more frequently in
areas with poor water quality
• Filter 3 to be changed a minimum of every 12 months, or more frequently in areas with
poor water quality
•
Indicative minimum replacement frequency:
1. Turn off water supply at the isolation tap
2. Remove the old filter cartridge (unscrew clockwise) until it stops. Pull the cartridge down
to remove the cartridge
3. Repeat steps 2 on the remaining cartridges
4. All cartridges are labelled with a number on the top left hand corner. Use the correct
numbered cartridge for the replacement. To order replacement cartridge see Page 8
5. Before installing the replacement filter cartridge, mark the installation date and the
replacement date (no later than 6 months for filter 1, 2 and 4, no later than 12 months for
filter 3) on the filter’s rating plate. Diarise the replacement date as a reminder
6. Insert and turn anti-clockwise until the cartridge stops
7. Once all cartridge have been replaced turn on the water supply
Old Cartridge
New Cartridge
1
Sediment and Dirt Particles Removal Cartridge
3 – 6 months
2
Chlorine, Taste/Odour Reduction Cartridge
3 – 6 months
3
Reverse Osmosis Membrane
12 – 24 months
4
Water Stabiliser
3 – 6 months or when
TDS is less than 60 PPM
1
2
3
3
2 1
4
4
1
2
3
3
2 1
4
4