HIPERFACE DSL encoders
Socket
Pin
Designation
Function
8|7|6|5|4|3|2|1
15|14|13|12|11|10|9
1
—
—
2
DSL−
Inverse HIPERFACE DSL signal (motor temperature
sensor evaluation over DSL communication)
3
—
—
4
DSL+
HIPERFACE DSL signal (motor temperature sensor
evaluation over DSL communication)
5
—
—
6
—
—
7
—
—
8
—
—
9
—
—
10
—
—
11
—
—
12
—
—
13
—
—
14
—
—
15
—
—
Tab. 49: X4A connection description for HIPERFACE DSL encoders
Cable requirements
Feature
All sizes
Max. cable length
100 m, shielded
Tab. 50: Cable length [m]
Information
To ensure proper functionality, we recommend using cables from STOBER that are matched to the complete system. If
unsuitable connection cables are used, we reserve the right to reject claims under the warranty.
Unsuitable encoder models
The following STOBER encoder models may
not
be connected:
Encoder model
Code according to type designation
ECI 1118
C0
EQI 1130
Q0
ECI 1319
CR
EQI 1329
QP
EQI 1331
QR
Tab. 51: Encoder models with unsuitable supply voltage range