7 | Connection
STOBER
48
05/2019 | ID 442793.01
7.4.3
X2A: Motor temperature sensor A
The motor temperature sensor of axis A is connected to terminal X2A. All device types of the SC6 drive controller have
connections for PTC thermistors. You can connect a maximum of two PTC triplets to X2A.
Information
Note that the evaluation of the temperature sensor is always active. If operation without a temperature sensor is
permitted, the connections must be bridged on X2. Otherwise a fault is triggered when switching on the device.
Information
Note that a temperature sensor does not have to be connected to terminal X2 for a HIPERFACE DSL encoder. In this case,
the temperature sensor signal is transferred together with the encoder signal over connector X4.
Term.
Pin
Designation
Function
7 | 8
7
1TP1+
PTC connection
8
1TP2−
Tab. 44: X2A connection description, motor temperature sensor A
For connecting wiring, observe the terminal specifications in the chapter
Cable requirements
Motor type
Connection
Size 0 to 2
Synchronous servo motor,
asynchronous motor
Without output choke
50 m, shielded
Synchronous servo motor,
asynchronous motor
With output choke
100 m, shielded
Lean motor
Standard
50 m, shielded
Tab. 45: Maximum cable length of the power cable [m]
7.4.4
X2B: Brake B
The brake of axis B is connected to X2B for double-axis controllers. Only X2A is available for single-axis controllers. The
connection description of X2B matches the X2A description.
7.4.5
X2B: Motor temperature sensor B
The motor temperature sensor of axis B is connected to X2B for double-axis controllers. Only X2A is available for single-axis
controllers. The connection description of X2B matches the X2A description.