8 | Commissioning
STOBER
74
05/2019 | ID 442793.01
Saving the test configuration
1.
In the project tree, highlight the drive controller to which you have transferred the test configuration and click on the
first projected axis in the project menu >
Wizard
area.
2.
Select the
Save values
wizard >
Action management
area and click on
Save values
.
3.
Since the configuration only takes effect after the drive controller is restarted, select the
Restart
wizard >
Action
management
area and click on
Restart
.
Activating the control panel and testing the project configuration
ü
The STO safety function must not be activated.
1.
Select
Jog control panel
.
2.
Click
Control panel on
and then
Enable
.
ð
The drive is controlled using the activated control panel.
3.
Move the axis step-by-step and test the direction of motion, velocity, distances, etc. using the
Jog+
,
Jog−
,
and
JogStep−
buttons.
4.
Optimize your project configuration based on your test results as necessary.
5.
To deactivate the control panel, click on
Control panel off
.
Information
Jog+ and Jog− cause a continual manual movement in the positive or negative direction. If both buttons are active, no
movement is executed.
and JogStep– move the drive relative to the current actual value by the increment specified in I14.
Jog+ and Jog− have a higher priority than and JogStep−.