STOBER
9 | Connection
05/2019 | ID 442790.01
85
9.4.6.1
AP6 interface adapter (resolver)
AP6A00 – resolver (9-pin to 15-pin)
Socket
8
Pin
Designation
Function
Pin
Connector
9
1 | 2 | 3 | 4 | 5
6 | 7 | 8 | 9
1
—
—
—
1|2|3|4|5|6|7|8|9
10|11|12|13|14|15
2
1TP1
—
—
3
S2 Sin−
Sin input reference potential
9
4
S1 Cos−
Cos input reference
potential
11
5
R1 Ref−
Resolver excitation signal
reference potential
2
6
1TP2
—
—
7
S4 Sin+
Sin input
1
8
S3 Cos+
Cos input
3
9
R2 Ref+
Resolver excitation signal
6
Tab. 71: AP6A00 connection description for resolver (9-pin to 15-pin)
9.4.7
X4B: Encoder B
The encoder of axis B is connected to X4B for double-axis controllers. Only X4A is available for single-axis controllers. The
connection description of X4B matches the X4A description.
Information
Note that a master encoder must be connected to axis A during
.
9.4.8
X9: Ethernet service interface
X9 is used to connect the drive controller to a PC with DriveControlSuite commissioning software installed.
Socket
Pin
Designation
Function
1|2|3|4|5|6|7|8
1
Ethernet communication
2
TxData−
3
R
4
—
—
5
—
—
6
RecvData−
Ethernet communication
7
—
—
8
—
—
Tab. 72: X9 connection description
Cable requirements
Feature
All sizes
Max. cable length
100 m, shielded
Tab. 73: Cable length [m]
8
View of 9-pin D-sub for connecting the SDS 4000-compatible resolver cable
9
View of 15-pin D-sub for connecting to terminal X4