8 | Installation
05/2019 | ID 442790.01
65
The following specifications apply to installation with Quick DC-Link DL6B:
DL6B dimensions
Size 0
Size 1, size 2
Horizontal fastening
holes
∅
4.2 (M5)
A
45
65
B
Size 0
46±1
56±1
B
Size 1, size 2
56±1
66±1
Vertical fastening
holes
∅
4.2 (M5)
D
393+2
393+2
Tab. 57: Drilling dimensions for Quick DC-Link DL6B [mm]
8.5
Length of copper rails
For the installation of the Quick DC-Link modules, you require three prepared copper rails with a cross-section of 5 ×
12 mm.
The length of the copper rails is 5 mm shorter than the total width of the group, i.e. the total width of all DL6B Quick DC-
Link modules present in the group:
B = A − 5 mm
Note that the correct length of the copper rails can be determined only after installation of all modules:
A
B
Fig. 17: Determination of the correct length of the copper rails
A
Total width of the group after installation
B
Length of the copper rails = A − 5 mm