Command
Description
Returned value
*gfifostr
Gyroscope “FIFO Stream” enable
st 0 0 0 0 0 0 IR FC FS
*gfifostf
Gyroscope “Stream-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*gfifobtf
Gyroscope “Bypass-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*gfifobts
Gyroscope “Bypass-to-Stream” enable
st 0 0 0 0 0 0 IR FC FS
*gfifodstr
Gyroscope “Dynamic Stream” enable
st 0 0 0 0 0 0 IR FC FS
*mfiforst
Magnetometer “Reset mode” enable
st 0 0 0 0 0 0 IR FC FS
*mfifomde
Magnetometer “FIFO mode” enable
st 0 0 0 0 0 0 IR FC FS
*mfifostr
Magnetometer “FIFO Stream” enable
st 0 0 0 0 0 0 IR FC FS
*mfifostf
Magnetometer “Stream-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*mfifobtf
Magnetometer “Bypass-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*mfifobts
Magnetometer “Bypass-to-Stream” enable
st 0 0 0 0 0 0 IR FC FS
*mfifodstr
Magnetometer “Dynamic Stream” enable
st 0 0 0 0 0 0 IR FC FS
*pfiforst
Pressure sensor “Reset mode” enable
st 0 0 0 0 0 0 IR FC FS
*pfifomde
Pressure sensor “FIFO mode” enable
st 0 0 0 0 0 0 IR FC FS
*pfifostr
Pressure sensor “FIFO Stream” enable
st 0 0 0 0 0 0 IR FC FS
*pfifostf
Pressure sensor “Stream-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*pfifobtf
Pressure sensor “Bypass-to-FIFO” enable
st 0 0 0 0 0 0 IR FC FS
*pfifobts
Pressure sensor “Bypass-to-Stream” enable
st 0 0 0 0 0 0 IR FC FS
*pfifodstr
Pressure sensor “Dynamic Stream” enable
st 0 0 0 0 0 0 IR FC FS
*PDON
Sets power-down pin
*PDOFF
Clears power-down pin
*STON
Sets self-test pin
*STOFF
Clears self-test pin
*HPON
Sets high-pass filter pin
*HPOFF
Clears high-pass filter pin
*FSON
Sets full-scale pin
*FSOFF
Clears full-scale pin
Note: IR: interrupt byte; FC: FIFO control register; FS: FIFO source register.
Set demonstration board
The command *setdbxxxvy selects the part of the firmware able to handle the adapter board sensor connected to
the board. e.g., in order to select the firmware for the LIS3DH the command must be: *setdb105V1. The D6 LED
(green) is automatically switched on.
Start command
The *start command initiates the continuous data acquisition. When this command is sent to the device, it returns
a string of bytes (plus carriage return and line feed) similar to “st OUT1 OUT2 OUT3 IR BT”.
The first two bytes are always the ASCII char “s” and “t” which correspond to the hexadecimal values {73h 74h}.
OUT1, OUT2, and OUT3 are the bytes that contain the values measured at device outputs; if the output data is
represented on more than 8 bits, OUT1, OUT2, and OUT3 are split into two bytes: high byte (e.g.: “XH”) and low
byte (e.g.: “XL”).
IR contains the interrupt bytes and BT contains the bytes that describe the state of the buttons integrated on the
board.
UM0979
Supported commands
UM0979
-
Rev 6