4
Use
Checks and actions prior to commissioning
is released. The throttle must not remain
activated or locked.
• Test that the truck brakes and stops when
the throttle is released while driving.
• Tilt the tiller, then release it. Check that the
tiller automatically returns to the vertical
position.
• Test that the truck brakes and stops when
the tiller is released while driving.
• Check that the truck brakes and stops when
the tiller is pushed all the way down while
driving.
• Check that the emergency shutdown
handle is operating correctly. Carry out
the test when travelling towards the forks.
• Check that the anti-crush/operator anti-
crush protective device is operating cor-
rectly.
• Check that the brake is operating correctly.
• Test that the electromagnetic brake works
effectively.
• Check that the battery harness is in good
condition.
• Check and test the battery electrolyte level
and density as indicated in the battery
instructions.
• The operator must be qualified to drive the
truck. The operator must be able to reach
the controls and operate them (especially
the anti-crush protective device). Do not
obstruct access to the controls.
• Check that the side protection panels are in
good condition and are operating correctly
(EXV-SF only).
• Visually check that the operator platform
is in good condition and that it is operating
correctly (EXV-SF only):
- Climb onto the operator platform and turn
on the truck.
- Test that the truck goes into forwards/re-
verse travel using the control throttle.
- Climb down from the step plate and
visually check that the operator platform
automatically moves to a rest position, tilted
slightly upwards.
- Stand to the side of the truck and make
sure that the area in front of and behind the
truck is clear.
- Using a boom, tilt the tiller without turning
and slightly rotate the control throttle
towards the forks. Repeat the sequence,
turning the throttle in the opposite direction.
In both cases, test that the truck remains at
a standstill. The truck must NOT move.
- Push the platform upwards. Push the
operator platform slightly to check that
it automatically moves into a vertical,
fully closed position. Caution: danger of
crushing hands!
- With the platform in a vertical position and
the side panels open, check that the truck
does NOT function!
• Check that the fork stop latches are in
good condition, operating and positioned
correctly (EXP only).
• Check that the fork stop latches are properly
and completely closed (EXP only).
• Check that the forks are locked and cannot
move accidentally (EXP only).
• Check for the presence and the correct
positioning of the mechanical stop that
prevents the unintentional extraction of
forks (EXP only).
68
45758043402 [EN]
Содержание EXP 14
Страница 2: ......
Страница 7: ...1 Introduction ...
Страница 16: ...1 Introduction Environmental considerations 10 45758043402 EN ...
Страница 17: ...2 Safety ...
Страница 29: ...3 Overview ...
Страница 67: ...4 Use ...
Страница 103: ...5 Maintenance ...
Страница 116: ...5 Maintenance Putting out of commission 110 45758043402 EN ...
Страница 117: ...6 Technical data ...
Страница 118: ...6 Technical data EXV and EXVi overall dimensions EXV and EXVi overall dimensions 112 45758043402 EN ...
Страница 119: ...Technical data 6 EXV SF and EXVi SF overall dimensions EXV SF and EXVi SF overall dimensions 45758043402 EN 113 ...
Страница 133: ...Technical data 6 EXP overall dimensions EXP overall dimensions 45758043402 EN 127 ...
Страница 140: ...6 Technical data Supply table 134 45758043402 EN ...
Страница 142: ...Index g Types of lifting masts 43 Triplex 44 U Update of this manual 4 136 45758043402 EN ...
Страница 143: ......
Страница 144: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 45758043402 EN ...