PROGRAMMING HOT KEYS 

 

 

 

 

 

 

 

You can program the above menu keys as follows. 

● 

Select the screen which you would like to assign to the key, from the group of screens 

● 

Press and hold the F1 key and press “Enter”. The function key has now been programmed. When you press 

the relevant function key the selected screen is displayed. 

 

You can program all the above function keys with screens from the relevant group. 

 

 

Example: 

 

In this example, we will program screen “611 Overview house 

temperature” under the info function key. Go to the main menu and then 

press key 6, followed by 1 and then 1 again. Press and hold F1 and press 

“Enter”. The function key has now been programmed. 

 

 

 

 

If you then press the 

 key screen 611 will be displayed. 

 

 

Restoring default setting hot keys: Press and hold the F1 key and press “function key”. We can clear the 

programmed 

 key from the example by pressing the key combination   + 

 . 

 

 

TERMINAL NUMBER IN-/OUTPUTS 

The terminal number of an input/output consists of the module address, the type of input/output and a 2-digit 

serial number. The module address is between 00 and 31. The type of input/output is indicated by a letter in 

accordance with the table below. The serial number must be between 01 and 99 (00 means that the 

input/output is not used). 

 

Type in-/output 

Letter  Serial number   Description 

0-10V output 

1-99 

Analogue output with a range of 0-10V or 10-0V. 

Relays output 

1-99 

Relay contact output (this does not include: alarm relay, 

pulse outputs etc.) 

Digital output 

1-99 

Opto coupler output (Max. 35Vdc 30mA). 

Open-/close control 

1-99 

Open-/close control with position feedback signal. 

This includes e.g. flaps with position feedback signal. 

30-230Vac output 

1-99 

Analogue output with a range of 30-230Vac or 230-30Vac. 

2-10V output 

1-99 

Analogue output with a range of 2-10V with position 

feedback signal. Among these are modules for controlling an 

EGM-100CA or EGM-250CA 

Air inlet flap 

1-99 

MCA flap, a wind compensated air inlet flap 

Temperature sensor 

1-99 

This includes all types of temperature sensor fitted with 10K 

NTC resistor (N10B, BV10B etc.) 

0-10V input 

1-99 

Analogue input with a measuring range of 0-10V. To connect 

measuring sensors such as RH, CO2, pressure etc. 

Digital input 

1-99 

This includes measuring fans, counter contacts etc. 

Meteo station 

1-99 

Module on which a wind speed meter, wind direction and a 

rain sensor can be connected to. 

 

 

 

group number 

Содержание PL-9400

Страница 1: ...USER MANUAL PL 9400 i POULTRY COMPUTER EN StienenBE PL 9400 G EN02000 PL 9400 PL 9400 i...

Страница 2: ...y questions Be sure to have all necessary data at hand To ensure a speedy solution to the malfunction and to avoid any misunderstandings it is advisable to note down the cause and the circumstances in...

Страница 3: ...eous controls 16 Temperature controls 16 Temperature monitoring 17 Compensations climate control 17 Temperature overview 25 Alarm 25 Thermo differential alarm 26 HOUSE STATUS 27 In use 27 Not in use 2...

Страница 4: ...utlet FSO push on the flap of the fixed socket outlet until you hear it click lock Alarm codes installation 39 SYSTEM 40 Display 40 MAINTENANCE AND CHECK UP 41 Appication notes Animal weighing PL9XIAW...

Страница 5: ...ieve the remaining settings and or measurements using the cursor up and down keys KEYBOARD Caution Only press the keys with the tip of your finger Sharp objects such as a pen pencil or screwdriver may...

Страница 6: ...or the next control if there are any controls of the same type such as ventilation groups left right recirculation etc Alarm key switching the main alarm on and off Hot key for alarm screen The LED in...

Страница 7: ...text will automatically start with an initial capital 4 NAVIGATION KEYS MENU CURSOR MODE Cancel This key cancels changes or menu option selections Press and hold this key to select the main menu Move...

Страница 8: ...tput is indicated by a letter in accordance with the table below The serial number must be between 01 and 99 00 means that the input output is not used Type in output Letter Serial number Description...

Страница 9: ...he Overview window After selecting this window you will have to enter the access code again to be able to change a setting ACCESS CODE You can use an access code to protect your computer against unaut...

Страница 10: ...r higher than 10 0 C is set this will be an absolute temperature setting Manure belt Heater block Always relative to temperature in the house n a Ventilation groups Always relative to temperature in t...

Страница 11: ...ouse also see Automatic bandwidth compensation on page 18 MINIMUM AND MAXIMUM VENTILATION If compensation depending on the fill ratio has been installed the minimum and or maximum ventilation will be...

Страница 12: ...not be displayed Minimum flap opening Maximum flap opening 100 Flap opening Minimum at ventilation Main ventilation Current ventilation Current flap opening Maximum at ventilation The AQC flap without...

Страница 13: ...en determining the flap positions The pressure control will be instantaneously switched off if a ventilation alarm occurs at the main ventilation control If a pressure alarm occurs the pressure contro...

Страница 14: ...ndwidth If the bandwidth is too small the heating very quickly reacts to temperature changes The switched heating has a fixed installer adjusted switching hysteresis Minimum maximum heating Limiting t...

Страница 15: ...ting immediately after you switch the house to not in use Reduction Limiting the current cooling and to prevent that too much cold air being drawn into the house when the outside tem1perature is low a...

Страница 16: ...drop in the house temperature specifically at the bottom of the house If the pressure control was not switched off the air speed and the temperature difference in the house would increase enormously A...

Страница 17: ...larm The temperature monitor alarm occurs only when a positive difference is detected not when the temperature drops down COMPENSATIONS CLIMATE CONTROL Compensations ensure that the setting is increas...

Страница 18: ...NTILATION Control of optimal ventilation based on the fill ratio The fill ratio is calculated on the basis of the maximum number of animals in the house and the current number of animals in the house...

Страница 19: ...minimum ventilation 1 0 C Start outside temperature 15 0 C till 10 0 C Current outside temperature 5 0 C 5 0 C 15 0 C 1 0 C 20 0 100 2 Calculated minimum ventilation 20 0 2 0 18 Current outside tempe...

Страница 20: ...pensated pressure is limited by the set minimum and maximum pressure RH The ventilation flap position and set house temperature can be controlled based on relative humidity Absolute RH the water vapou...

Страница 21: ...he heaters can switch on Absolute RH outside air lower than the absolute RH house If the RH of the outside air is low the humidity in the house can be removed by increasing the ventilation rate The co...

Страница 22: ...use becomes too high this also automatically increases the heating settings The corrected ventilation is limited by the pre set maximum Max Compensation ventilation In this event ventilation is NO LON...

Страница 23: ...lation The corrected ventilation is limited by the pre set maximum Max Correction ventilation Compensation current CO2 CO2 compensation start 100ppm factor 1 Factor If 0 0 is set this means that RH co...

Страница 24: ...immediately be adjusted to the curve setting The settings obtained from a growth curve are recalculated every hour to achieve a more gradual development of the setting Press function key F3 to display...

Страница 25: ...absolute alarm limit is reached This compensation prevents the alarm from being activated unnecessarily when outside temperatures are high However the corrected alarm limit can never be higher than th...

Страница 26: ...perature limits and the preset temperature of the control itself GROUPS VENTILATION If the measuring fan is switched off it no longer influences the control and alarm functions of the main ventilation...

Страница 27: ...off all flaps are closed all timers are switched off In addition in this screen you can switch the growth curve on off and change the day numbers of the curves New entry Change the setting no to yes...

Страница 28: ...hese 2 have been added the amount filled is automatically set to 0 Use keys 0 9 to change the name see page 7 FILLED An overview of the last 5 times that you have entered the filling details in screen...

Страница 29: ...Attention Counter readings which are a copy of the counter readings on the PFA 9200 or PFV 9200 are not deleted you can only delete them on the PFA 9200 or PFV 9200 Caution When the counter is cleared...

Страница 30: ...1 311 1 314 2 625 Sunday 1 047 1 140 2 187 Saturday 1 098 1 102 2 200 Friday 1 002 1 035 2 037 Thursday 1 049 1 122 2 171 Wednesday 1 053 1 130 2 183 The weekly total is the sum of the counter readin...

Страница 31: ...you to quickly switch schedules LIGHT TIMERS Light timers enable a light regulation to be used so that the lights are gradually switched on off A light regulation enables you to create ideal day and n...

Страница 32: ...age For feed dosing the amount actually fed is compared to the amount setting Feeding stops when the pre set amount is reached even if the stop time has not been reached yet A feed dosing alarm is gen...

Страница 33: ...trol you can set the day number of the dosing curve here If the installer has activated the dosing curves you can use programmable curves to have the amount of water and or feed per animal increase au...

Страница 34: ...e consisting of time schedules Standard timer TIME SCHEDULES You can set a maximum of 9 different time schedules Every time schedule can consist of a maximum of 24 periods LIGHT SCHEDULES You can set...

Страница 35: ...y Friday etc to Monday If the PL 9400 poultry computer is linked to a feed weighing computer you CANNOT change the setting First day of the week and the setting Beginning new day on the PL 9400 poultr...

Страница 36: ...this moment per group of animals Today s mortality or death rate is increased automatically by the value entered after which the entry is erased Dead Today Today s total mortality If you have entered...

Страница 37: ...n the sum of the total number of animals of all animal groups added together Entry date The poultry computer uses these Entry date to calculate the animal age Beside that the Entry date is used to fil...

Страница 38: ...per name This screen allows you to switch the external alarms on or off max 10 In addition the next screen shows the current status of the input opened or closed and the current alarm status COMMUNICA...

Страница 39: ...ounter selected for water dosing or the timer type is set to communication and no PFA 9200 has been installed Invalid silo output The output number does not exist on the module Minimum supply alarm Th...

Страница 40: ...for all components although a certain amount of feed has to be dosed Dosage too low The amount of water and or feed dosed is less than the preset minimum amount to be dosed see page 35 Feed detected...

Страница 41: ...ion of the filters and flaps Check for air pressure leakage in the house Air leaks can lead to draughts and in summer they can result in unwanted heating due to hot air being drawn in from between the...

Отзывы: