ALARM CODES INSTALLATION
Alarm code
Description
Module x not found
●
The module number set for the terminal does not exist
●
Poor or no connection between PL-9200-MODULE and module.
●
The connection cable between the PL-9200-MODULE and the PL-9200 bottom
PCB is missing or is loose.
Module x absent
Module address not found, check the settings on the module
Module x reset alarm
Module continues to reset due to a fault, check the module
No communication address Missing device address PL-9400 and/or PFB-35/70.
Communication
Main station has not received data from the displayed device address.
Output already assigned
The output has been assigned to two or more controls.
Input already assigned
The input has been assigned to two or more controls.
Invalid output
The output number does not exist on the module.
Invalid input
The input number does not exist on the module.
No output assigned
No output terminal number entered
No input assigned
No input terminal number entered
Wrong output type
The type of output set does not comply with the type of output which the control
can drive
Wrong input type
The type of input set does not comply with the type of input which the control
can use for its control operation
Unknown terminal type
This type of terminal does not exist
Wrong terminal setting
Faulty allocation. The function you have assigned to the terminal is not supported
by the module.
Counter already assigned
The counter has been assigned to two or more controls.
No outside sensor
The control installed requires an outdoor sensor but no outdoor sensor has been
installed
No pressure control
The control installed requires a pressure control but no pressure control has been
installed
Invalid counter
The type of counter is different from the type of timer (e.g. feed counter selected
for water dosing or the timer type is set to communication and no PFA-9200 has
been installed).
Invalid silo output
The output number does not exist on the module.
Minimum supply alarm
The counter did not reached the minimum setting within the time set.
Maximum supply alarm
The counter exceeds the maximum setting within the time set.
Invalid combination
Both the dosing timer and the animal group have been set to “communication”.
This is not allowed. You can either set only dosing timers via communication
(augers) or you can send the animal data via communication (valves).
Ventilation too low
1
The ventilation measured is below the minimum alarm limit calculated
Ventilation too high
1
The ventilation measured is higher than the maximum alarm limit calculated
Outside sensor faulty
Value measured by outside temperature sensor < -50.0°C or > +50.0°C
Temperature sensor faulty Value measured by temperature sensor < -50.0°C or > +100.0°C
RH sensor faulty
The RH sensor value measured is outside the preset limits
Pressure sensor faulty
The pressure sensor value measured is outside the preset limits.
CO2 sensor faulty
The CO
2
sensor value measured is outside the preset limits
Potentiometer faulty
The value measured by the potentiometer is outside the limits (EGM 100P, winch
motors etc.)
Sensor faulty
The values measured by the sensor (temperature, RH, CO
2
, pressure etc.) are
outside the preset limits
Invalid period x
●
The times set for a timer must be ascending and the difference between
“Begin” and “End” must be at least 1 minute.
●
The starting time (Begin) + the running time (Propagation time) of a light
control must not be after the next starting time (the time can be
simultaneous with the next starting time)
Beginning new day in period The “Beginning new day” time is in a period; this is not allowed. The
“Beginning
new day” time MUST BE BEFORE the first period.
Extern.alarm x
Your installer can change the names of the “External alarms” in to any name of