Page 18 of 41
TEMPERATURE
Activate the temperature compensation to prevent rapid temperature drops in the house (which usually occur in
the spring and autumn).
“Reduce temp. compensation”:
Determines the speed at which the corrected house temperature is
controlled down to the preset house temperature in the event of a
drop in temperature.
Switch off temperature compensation:
Set a maximum temperature compensation of 0.0°C.
Example:
Temperature exceeded
= Current house temperature - (House temperature s bandwidth)
= 28.1 °C - (20 °C + 4.0 °C) = 4.1 °C
However, the temperature correction can never be more than the
maximum temperature compensation. This means that in the above
example it can never be more than 3.0°C (maximum setting)
instead of 4.1 °C (calculated excess value). The corrected
temperature setting becomes equal to: house temperature s
temperature correction = 20.0 °C + 3.0 °C = 23.0 °C.
In this example, the time in which the house temperature is
controlled back to the temperature setting is:
(House temperature correction / max. temperature compensation) x
1 hour => (3.0°C / 0.2 °C) x 1 hour = 15 hours.
VENTILATION
Control of optimal ventilation based on the fill ratio. The fill ratio is calculated on the basis of the maximum
number of animals in the house and the current number of animals in the house (animal group 1 + animal
group 2).
BANDWIDTH COMPENSATION
If the outside temperature is part of the installation, the bandwidth of the main ventilation and/or air inlet flaps
can automatically be adjusted to changes in outside temperature.
Setting bandwidth compensation to obtain:
•
A larger bandwidth at low outside temperature.
•
A smaller bandwidth at high outside temperature
Current temperature outside = 10°C
Current temperature outside = 30°C
This setting is used to adjust the bandwidth to the current outside temperature.
House temperature setting
20.0 °C
Maximum temperature compensation
3.0 °C
Reduce temperature compensation
0.2 °C/h
Bandwidth
4.0 °C
Current house temperature
28.1 °C
Corrected setting house temperature
23.0 °C
Max.
Min.
V
e
n
ti
la
ti
on
[%
]
House temperature [°C]
Reduction per hour
20
25
30
23
3
°
C
0°C
30°C
40°C
3°C
0°C
6°C
1°C
2°C
4°C
5°C
7°C
8°C
20°C
10°C
C
orr
ec
te
d b
andw
idt
h [
%]
Outside temperature [°C]
Bandwidth diminished
from 4.0°C to 3.0°C
0°C
30°C
40°C
3°C
0°C
6°C
1°C
2°C
4°C
5°C
7°C
8°C
20°C
10°C
Outside temperature [°C]
C
orr
ec
te
d b
andw
idt
h [
%]
Bandwidth increased
from 4.0°C to 5.0°C