Page 14 of 41
HEATINGS
CONTROLLED HEATING
Heating
You can switch the heating on or off.
Temperature setting
The temperature on the basis of which the heating controls is relative to the house temperature, see page 10, if
a temperature of below 10.0°C is set. If a temperature equal to or higher than 10.0°C is set, this will be an
absolute setting.
Growth curve
If the cursor is on Growth curve temperature and you press the confirmation key the curve of the heating will
be displayed. You may change the curve settings or switch off the curve. Press the cancel key to return to the
previous screen. If you have switched off the curve, the text 'growth curve' will be replaced by the standard text
and you can no longer access the curve from this screen (the curve is off).
Bandwidth
The bandwidth determines the 'sensitivity' of the heating for temperature changes. The heating is controlled
from minimum to maximum within the bandwidth. If the bandwidth is too small, the heating very quickly reacts
to temperature changes. The switched heating has a fixed, installer-adjusted, switching hysteresis.
Minimum/maximum heating
Limiting the minimum/maximum force (heating capacity) of a controlled heating.
Current temperature
The current average temperature of the assigned sensors is displayed. Up to 4 temperature sensors can be
assigned to a heating control.
Current heating
Display of the current status of the heating and the calculated current flap position and/or heating capacity.
If -0% is calculated for the current heating (or the heating is switch off), the stop voltage will be sent out
instead of the minimum voltage setting (if house status = in use). If "Minimum heating" is activated, the
"minimum" voltage is applied to the output when the current temperature exceeds the temperature setting.
The current flap position or the current heating capacity is only displayed with controlled heating.