FLX-E Operations Manual Rev F
Page 40
Table of Contents
Top
Device Model Codes:
0 = INVALID DEVICE TYPE
1 = FLX-E 80 4 LZ,
2 = FLX-E 80 4 CV,
3 = FLX-E 160 2 LZ,
4 = FLX-E 160 2 CV,
5 = FLX-E 320 1 CV,
6 = FLX-E 80 4 LZ Dante,
7 = FLX-E 80 4 CV Dante,
8 = FLX-E 160 2 LZ Dante,
9 = FLX-E 160 2 CV Dante,
10 = FLX-E 320 1 CV Dante,
Amp State Code:
0 = POWER UP
1 = NORMAL
2 = AMP OVERTEMP WARNING
3 = AMP OVERTEMP SHUTDOWN
4 = AMP OVERTEMP SHUTDOWN RECOVERY DELAY
5 = AMP OVERLOAD SHUTDOWN
6 = CHANNEL RESET DELAY
7 = CHANNELS DISABLED
8 = CHANNELS RESET TO NORMAL
9 = SYSTEM WAKEUP
10 = SYSTEM LOAD TEST
11 = SYSTEM IN OVERTEMP WARNING
12 = SYSTEM IN OVERTEMP SHUTDOWN
13 = AMP IN OVERLOAD DISABLE
4.
START LOAD TEST
Command code: 0x2A
Description: command to start a system load test
Host sent data
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x2A
command code
Byte 5 = 0x02
take load test values
Byte 6 = 0xXX
8-bit sum of bytes 1 through 6