FLX-E Operations Manual Rev F
Page 52
Table of Contents
Top
23.
TOGGLE PREMIX MUTE
Command code: 0x59
Description: command used to toggle the premix mute on specified channel
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x59
command code
Byte 5 = 0xXX
channel number
Byte 6 = 0xXX
8-bit sum of bytes 1 through 5
FLX-E Response
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x59
command code
Byte 5 = 0xXX
command response, 0 = error, 1 = success
Byte 6 = 0xXX
8-bit sum of bytes 1 through 5
24.
PREMIX MUTE ON
Command code: 0x5A
Description: command used to mute a specified input channel
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1..8 is single channel
Host sent data
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x5A
command code
Byte 5 = 0xXX
channel number
Byte 6 = 0xXX
8-bit sum of bytes 1 through 5
FLX-E Response
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length