Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x02
start of message character
Byte 1 = 0x14
command code
Byte 2 = 0xXX
channel number
Byte 3 = 0x03
end of message character
FLX-E Response
Byte 0 = 0x02
start of message character
Byte 1 = 0x14
command code
Byte 2 = 0xXX
channel number
Byte 3 = 0xXX
current mute state (0 = mute off, 1 = mute on)
Byte 4 = 0x03
end of message character
21.
GET PREMIX ATTENUATION
Command code: 0x15
Description: command used to get the premix attenuation for a specified channel
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x02
start of message character
Byte 1 = 0x15
command code
Byte 2 = 0xXX
channel number
Byte 3 = 0x03
end of message character
FLX-E Response
Byte 0 = 0x02
start of message character
Byte 1 = 0x15
command code
Byte 2 = 0xXX
channel number
Byte 3 = 0xXX
current attenuation in 1 dB steps (e.g., 0x0A is 10dB attenuation)
Byte 4 = 0x03
end of message character
22.
GET PREMIX MUTE
Command code: 0x16
Description: command used to get the premix mute status for a specified channel
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x02
start of message character
Byte 1 = 0x16
command code
Byte 2 = 0xXX
channel number