![Stephill SSD10000S Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/stephill/ssd10000s/ssd10000s_operation-manual_1372635018.webp)
SSD10000S - SSD10000S/3PH
17
Once a start request is made the DSE 3110 will energise the
pre-heat
relay over a period of 10 seconds.
Once the engine is running and all starting timers have expired, the animated icon is displayed.
Fig.10 shows the page order when pressing the navigation button.
A red LED light will be illuminated above the button.
The generator is now ready to receive start/stop requests from the remote connections.
When scrolling manually, the display will automatically return to the Status page if no buttons are pressed for
the duration of the LCD Page Timer.
If the engine fails to fire during this cranking attempt then the starter motor is disengaged for the crank rest
duration after which the next start attempt is made.
Starting Sequence
Then the DSE 3110 will then attempt to crank the engine by operating the starter motor relay and also the
fuel pump relay.
Should this sequence continue beyond 3 attempts, the start sequence will be terminated and the
Failed to
Start
icon is displayed on the LCD screen.
(See Fault Finding - DSE 3110)
Timer Icon
Timer Icon
When the engine fires, the starter motor is disengaged. (The DSE 3110 de-energises the starter motor relay
once it detects an output frequency (Hz) from the main alternator).
It is possible to scroll to display the different pages of information by repeatedly operating the navigation
button.
Engine Running
AUTO MODE - Start/Stop Operation
Engine Running
Viewing the Instruments
Activate auto mode by pressing the button. The icon will be displayed on the LCD screen to
indicate the DSE 3110 module is in
AUTO MODE
if no alarms are present.
When the module is controlling the engine (starting and stopping) an animated (rotating) timer icon will be
displayed in the icon area to indicate that a timer is active, for example cranking time, crank rest, stopping
Once selected the page will remain on the LCD display until the user selects a different page or after an
extended period of inactivity, the module will revert to the status display.
Failed to Start