![Stentorfield Contour Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/stentorfield/contour/contour_operators-manual_1372177032.webp)
30
Operator’s Manual
Problem Solving
In the unlikely event of the machine developing a problem, details are given in the table
below (figure 3) on how to deal with common faults that can be easily remedied by
the operator.
Safety First! Should the remedy given below not cure the problem, or the
fault is not listed, DO NOT ATTEMPT TO CURE THE FAULT YOURSELF.
Contact your machine supplier for assistance.
Figure 3
Fault
Possible Cause
Remedy
Waste tray overflowing
Level sensor incorrectly
Ensure sensor is placed
located or jamming
correctly in the tray
Incorrect drinks
Ingredient canisters
Refit canisters into their
dispensed
located incorrectly
correct positions
Leaking from dispense
Mixing bowls/chambers
Refit correctly and ensure
area
fitted incorrectly
that all mixing stations
are water tight
Low water showing
Water supply
Ensure water supply is
on LCD display
turned off
turned on at stop-tap
Blank LCD display
Electricity supply
Ensure electricity supply
turned off
is turned on at the mains
Cups jamming
Incorrect cup size
Remove cups from cup
turret and replace with
correct size cups
No change given
(i) Coin tubes jamming
Clear coin tubes and
from change-giver
check for blockage
(where fitted)
(ii) Coin tubes empty or
Check and refill coin tubes
below pre-set level
where necessary
Coffee brewer unit
(i) Incorrect paper fitted
Remove and fit correct
jamming
90mm filter paper
(ii) Filter paper loaded
Reload paper and ensure
incorrectly
that it feeds correctly
(iii) Paper fouling on
Adjust brewer guard.
brewer guard
DO NOT REMOVE