Maintenance Manual STEMME S10-VT
Date of Issue: Jan. 01, 1998
Page 7-33
Amendment Nr.2
Date: March 23, 1998
A4011121_B23.doc
Doc. No. A40-11-121
7.8 Communication and Navigation Equipment
Description:
See section 3.8
During inspection and scheduled maintenance the following points must be observed:
Check, if Com- and Nav-equipment installed correspond to the equipment lists.
Check for correct installation and tight attachment.
Check condition, function and - if applicable - records of operating times of the Com- and Nav-equipment.
Check any antenna installed for condition, intended function and tight attachment.
Maintenance, inspection and adjustment of equipment installed according to the equipment list are performed
according to instructions of the equipment manufacturers (documents see Annex A).
NOTE:
If equipment is changed, the instructions in section 3.8 and 9 must be observed.
Changes of equipment without additional certification is only allowed, if devices according to the equipment
lists in section 9 are installed. Only these devices have been approved during certification and a faultless
operation with respect to certification requirements are granted by the airframe manufacturer. Further more in
countries other than Germany, equipment to be installed and operated must be certified in the country, in
which the aircraft is registered.
Upon changing of equipment and prior to operation, the equipment list and, if relevant, the weight and
balance report must be updated. A following inspection must establish and sign for compliance with the type.
If equipment not included in the Maintenance Manual was installed, compliance with the relevant
airworthiness requirements must be shown to the relevant aviation authority prior to the installation
(modification to the individual aircraft, "major modification").
7.9 Oxygen Equipment
Description:
See section 3.9
Oxygen System Mounting:
Check the oxygen system mounting, if installed as optional equipment, for condition and tight fit of
components.
Oxygen System:
Perform maintenance on the oxygen system in accordance with the instructions of the manufacturer (see
Annex A).