14 - MAINTENANCE

The appliance is required to be inspected at least once a year by a professional service person.  The compartment below firebox (behind 
lower access panel) must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting, 
bedding materials, or other fibrous materials. It is imperative that the burner be cleaned once a year.

A. VENT SYSTEM

• 

Annual examination of venting system by a qualified agency is required.

• 

IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL 

INSTALLATION. 

• 

The flow of combustion air must not be obstructed.

B. GLASS CLEANING & REPLACEMENT

• 

Clean glass only when cool and only with non-abrasive cleansers.

• 

Do not operate this fireplace with glass/frame assembly removed, cracked or broken.

• 

The glass assembly shall only be replaced as a complete unit, as supplied by Stellar Hearth Products.

• 

Replacement of glass & frame assembly, must only be performed by a licensed or qualified service person. 

 

DO NOT SUBSTITUTE MATERIALS. 

• 

Do not strike or slam glass door assembly.

C. REPLACEMENT PARTS LIST

PART

MANUFACTURER

PART NUMBER

Powervent

Enervex

SEE PAGE 15

Valve

Honeywell Smart Valve

SV9501

Pilot

Honeywell Smart Valve

Q3450C1185

Vacuum Switch

Cleveland Controls

AFS-405

Flue Pipe

Approved

SEE PAGE 15

24vac Transformer

Dayton

24vac 40 VA

Orifices

Custom

SEE PAGE 6

Glass Media

American Specialty Glass

GLACIER ICE

Glass Panel Sizes

CONTACT STELLAR DIRECTLY

VALVE AND ELECTRICAL ACCESS

There is an access panel in the floor of the firebox should more extensive service be needed.  Remove the inner and outer glass panels.  
Remove the glass media on the end with the pilot.  The end floor lifts out; remove the screws and lift it out. Remove the burner and loosen 
the pilot bracket.  There is a panel under the floor you removed. Remove the 6 screws and slide the panel up. 

CAUTION:  LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE 

IMPROPER AND  DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. KEEP APPLIANCE AREA 

CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. VAPORS 

AND LIQUIDS.

NOTE:    INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY  QUALIFIED SERVICE PERSON. THE APPLIANCE 

SHOULD BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED  SERVICE PERSON. MORE FREQUENT CLEANING  

MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIALS, ETC.  IT IS IMPERATIVE THAT 

CONTROL COMPARTMENTS, BURNERS AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

Содержание 4-BY-2-GL

Страница 1: ...y electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Страница 2: ...INS_GALAXY SERIES_BY REV C Page 2...

Страница 3: ...izontal Cap Location Clearances 16 17 F Vertical Cap Location Clearances 18 G Roof Termination Cap Installation 19 H Wall Termination Cap Installation 20 I Outside Air Intake 21 J Changing Outside Air...

Страница 4: ...ian Safe T Touch units only Clean glass only when cool and only with non abrasive cleansers Safe T Touch units only Do not operate this appliance with the glass frame assembly removed cracked or broke...

Страница 5: ...OA A B C D E F G H I 4 BY 2 GL 8 10 48 25 32 1 239 24 610 24 610 18 9 16 471 53 3 4 1 365 26 7 8 683 24 610 42 1 067 50 1 270 5 BY 2 GL 8 10 60 25 32 1 544 24 610 24 610 18 9 16 471 65 3 4 1 670 32 7...

Страница 6: ...D ON THE FACE OF THE FIREPLACE BELOW THE BOTTOM VIEWING EDGE ONLY 1 25 6 152 Figure 2B WARNING NON COMBUSTIBLE ZONE USE ONLY NON COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF FIREPLACE DO NOT...

Страница 7: ...7 Complete electrical hook up 8 Complete venting installation 9 Install facing material mantel or cabinetry 10 Install logs or glass and ember material or media 11 Verify proper operation of fireplace...

Страница 8: ...EPLACE IS NOT LOAD BEARING NOTE OTHER CLEARANCES APPLY ALL CLEARANCES MUST BE MAINTAINED A STANDOFF INSTALLATION STEP 1 Locate the standoffs on top of the fireplace Standoffs STEP 2 Remove the screws...

Страница 9: ...in manual bag with each fireplace Nailing tabs mount here for single sided see through and pier fireplaces STEP 1 Remove two screws Place nailing tabs and replace the two screws STEP 2 Fold out small...

Страница 10: ...EARANCE TO THE B VENT MUST BE MAINTAINED 4 FRAMING FLUE B VENT J J K K FLUE B VENT J L K J L K 6 A C B NOTE Make sure fireplace is square in both directions prior to finishing it or the glass will not...

Страница 11: ...FRAMING NOTE Framing dimensions should allow for wall covering thickness and fireplace facing materials When using a hearth adjust rough opening size as necessary to maintain at least minimum clearanc...

Страница 12: ...E BY A LICENSED OR QUALIFIED SERVICE PERSON WARNING DO NOT REMOVE GLASS ASSEMBLY WHEN HOT NOTE GLASS REMOVAL AND INSTALLATION MUST BE PERFORMED WITH TWO PEOPLE NOTE Glass must be removed using quality...

Страница 13: ...igure 6B 3 5 Place the long horizontal trim piece between the lower glass clips Slide back against the vertical trim piece See Figure 6B 3 and Figure 6B 4 Outer Glass Edge Protectors 6 For the panes o...

Страница 14: ...r Propane CAUTION Installation of the gas line must only be done by a qualified person in accordance with local building codes if any If not follow ANSI 223 1 NOTE The appliance and its individual shu...

Страница 15: ...4 RSIF180 120 5 8 35 Refer to the vent systems manufacturer s installation manual for complete installation instructions Installation must conform with the venting requirements and restrictions as out...

Страница 16: ...to prevent condensation on window D Ventilated soffit 24 610 mm E Unventilated soffit 12 305 mm F Outside corner 12 305 mm G Inside corner to non combustibles 12 305 mm H Meter Regulator Not to be ins...

Страница 17: ...n combustible I Combustible Non combustible 12 305mm C Clearance from corner in recessed location Combustible 24 609 6mm Non combustible 12 304 8mm D Minimum width for back wall of a recessed location...

Страница 18: ...TO 10 12 2 5 0 76 OVER 10 12 TO 11 12 3 25 0 99 OVER 11 12 TO 12 12 4 0 1 22 OVER 12 12 TO 14 12 5 0 1 52 OVER 14 12 TO 16 12 6 0 1 83 OVER 16 12 TO 18 12 7 0 2 13 OVER 18 12 TO 20 12 7 5 2 27 OVER 2...

Страница 19: ...G POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO MATCH BASE INSULATION PAD STEEL CHIMNEY ADAPTER POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO MATCH BASE INSULATION PAD MECHANICAL FLU...

Страница 20: ...WER VENT DRILL 1 4 HOLES TO MATCH POWER VENT BASE USE APPROPRIATE HEAVY DUTY FASTENERS TO SECURE POWER VENT DRILL 1 4 HOLES TO MATCH POWER VENT BASE ACCESS PANEL NEEDED FOR FUTURE DAMPER SERVICE Wall...

Страница 21: ...take connections on the side and the bottom of the fireplace Use chart on Page 15 to determine which size outside metal pipe you should use for your fireplace Connect only to metal intake pipe or Stel...

Страница 22: ...4 4 9 7 8 HP 1 10 1 7 1 4 1 2 To light the fireplace Activate the switch The fireplace has a pre and post timer set at the factory for 30 seconds The powervent and flame will not turn on for 30 60 sec...

Страница 23: ...ace Activate the switch The fireplace has a pre and post timer set at the factory for 30 seconds The powervent and flame will not turn on for 30 60 seconds after switch is activated and the powervent...

Страница 24: ...INS_GALAXY SERIES_BY REV C Page 24 9 GALAXY ELECTRIC Figure 9C 1 Terminals 1 2 C 1 TERMINALS 1 2 LED Lights Figure 9C 2 Terminals 3 4 C 2 TERMINALS 3 4 Main Flame...

Страница 25: ...Page 25 INS_GALAXY SERIES_BY REV C 9 GALAXY ELECTRIC Figure 9C 3 Terminals 5 6 C 3 TERMINALS 5 6 Fireplace Power Figure 9C 4 Terminals 7 8 C 4 TERMINALS 7 8 Powervent Connection...

Страница 26: ...NS_GALAXY SERIES_BY REV C Page 26 9 GALAXY ELECTRIC NOTE OPTIONAL IF A DAMPER IS NOT USED DO NOT CONNECT ANYTHING TO TERMINALS 9 10 Figure 9C 5 Terminals 9 10 C 5 TERMINALS 9 10 Flue Damper Connection...

Страница 27: ...age 27 INS_GALAXY SERIES_BY REV C 9 GALAXY ELECTRIC NOTE OPTIONAL IF A DAMPER IS NOT USED TERMINALS 11 AND 12 HAVE A JUMPER ACROSS THEM Figure 9C 6 Terminals 11 12 C 6 TERMINALS 11 12 Flue Damper Prov...

Страница 28: ...non combustible area mentioned in B D Combustible finishing materials allowed E Combustible mantel may be placed above the top of the glass viewing area F Combustible hearth may be placed below the bo...

Страница 29: ...liance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water WHAT TO DO IF...

Страница 30: ...place on at switch OFF 2 ON 5 Figure 11B 11 LIGHTING SHUTDOWN STOP Read safety information on previous page and front cover of this manual before continuing NOTE This fireplace is equipped with an ign...

Страница 31: ...R KIND OF MEDIA WITHOUT WRITTEN APPROVAL OF STELLAR HEARTH PRODUCTS Figure 13 Place the supplied glass media into the base tray Cover the base evenly Do not use more than the supplied amount Do not ge...

Страница 32: ...SEE PAGE 15 Valve Honeywell Smart Valve SV9501 Pilot Honeywell Smart Valve Q3450C1185 Vacuum Switch Cleveland Controls AFS 405 Flue Pipe Approved SEE PAGE 15 24vac Transformer Dayton 24vac 40 VA Orif...

Страница 33: ...ew home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever o...

Страница 34: ...wing Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under...

Отзывы: