8 - VENTING
A. APPROVED VENTING
B. HORIZONTAL VENT SYSTEM CLEARANCES
ALL APPROVED VENTING
TOP
BOTTOM
SIDES
HORIZONTAL
1 inch (25mm)
1 inch (25mm)
1 inch (25mm)
C. WALL PASS-THROUGH - Follow all local codes for requirement of firestops.
CAUTION: Consult the local and national installation codes to assure adequate combustion and ventilation air is available.
NOTE: Flame height and appearance will vary depending upon venting configuration and type of fuel used. Venting
requirements apply to both Natural and Propane gas.
STOP: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL.
SPECIFICATIONS
MODEL #
DESCRIPTION
B-VENT
OA
REG PV
IN-LINE PV
VOLTS
AMPS
HP
4-BY-2-GL
4X2 BAY
8”
10”
RSO12
RSIF160
120
5.8
.35
5-BY-2-GL
5X2 BAY
8”
10”
RSO12
RSIF160
120
5.8
.35
6-BY-2-GL
6X2 BAY
10”
10”
RSO14
RSIF180
120
5.8
.35
7-BY-2-GL
7X2 BAY
10”
10”
RSO14
RSIF180
120
5.8
.35
4-BY-3-GL
4X3 BAY
8”
10”
RSO12
RSIF160
120
5.8
.35
5-BY-3-GL
5X3 BAY
8”
10”
RSO12
RSIF160
120
5.8
.35
6-BY-3-GL
6X3 BAY
10”
10”
RSO14
RSIF180
120
5.8
.35
7-BY-3-GL
7X3 BAY
10”
10”
RSO14
RSIF180
120
5.8
.35
Refer to the vent systems manufacturer's installation manual for complete installation instructions.
Installation must conform with the venting requirements and restrictions as outlined in this manual.
SEE CHART ABOVE FOR SIZE diameter B-Type Venting that must be used. UL/CSA approved B-Vent only.
DO NOT decrease the vent size.
Vent runs are approved for up to 110 feet with quantity of 11, 90 degree elbows. This is not the case with all instances.
You must have venting scenario approved by Stellar Hearth Products.
Available In-Line Power Venting
An in-line power vent (RSIF series from Enervex) is approved for use with Stellar fireplaces.
The in-line powervent must be specified and approved for use by Stellar Hearth. Vent runs after the in-line powervent may use a pressure approved
pipe, but it is not required. If you use B-Vent after an in-line powervent it is crucial that all pipe and elbow joints, and the longitudinal seam are sealed
using an high heat approved mastic or foil tape.
NOTE: All pipe and elbow joints must be sealed. This includes the longitudinal seam on the pipe.
High Temp RTV Silicone and/or foil tap MUST be used on each joint/seam.
Failure to do so may cause lack of vacuum and may not trigger the vacuum switch.