Rail Runner Gen III
Rail Runner Gen III Operator’s Manual
20
Tab. 1.
Symbols of connected modules
Symbol
Description
Motorized vertical slide (option).
Tracking sensor (option).
Use the knobs to set the required parameters (Tab. 2). Rotate to the right to increase
the value of the parameter. Rotate to the left to decrease the value.
Tab. 2.
Parameters shown on the main screen
Parameter Value
Description
Method of control
0
–5 s [step: 0.1]
(with tracking off)
0.2
–5 s [step: 0.1]
(with tracking on)
Oscillation dwell time
in left position.
Press and hold
and rotate
0
–5 s
[step: 0.1]
Oscillation dwell time
in center position.
Press and hold
and rotate
0
–5 s [step: 0.1]
(with tracking off)
0.2
–5 s [step: 0.1]
(with tracking on)
Oscillation dwell time
in right position.
Press and hold
and rotate
0.1
–11.8 cm
0.04
–4.5 in
[step: 0.1/0.01]
Oscillation width.
Press and release
(activates
) and rotate
10
–200 cm/min
5
–78 in/min
[step: 5/1]
Oscillation speed
(when the vertical
slide is not connect-
ed).
Rotate
Oscillation speed
(when the vertical
slide is connected).
Press and release
(activates
) and rotate
0
–250 cm/min
0
–98 in/min
[step: 1/0.5]
Carriage speed.
Rotate
Travel the carriage
with the maximum
speed in the direction
set by the direction
switch.
Press and hold
when the
arc
ignition switch is set to ‘O’
From
–9.9 to +9.9
cm
From
–3.9 to +3.9 in
[step: 0.05/0.02]
Oscillation offset.
Rotate
From
–2.5 to +2.5
cm
From
–1 to +1 in
[step: 0.02/0.01]
Torch height
(when the vertical
slide is connected).
Rotate