718.573 | 11.27
10. Technical Data
The technical data is subject to alterations by the manufacture.
Electrical Data
Operating voltage
12 V or 24 V;
automatic recognition
Voltage range 12 V
6.9 V – 17.2 V
Voltage range 24 V
17.3 V – 43.0 V
Permitted operating
temperature range
–10 °C to +50 °C
Permitted storage
temperature range
–20 °C to +80 °C
Power consumption mA
12,5 mA @ 12 V; 15,8 mA @ 24 V
PWM-Frequency
30 Hz
Maximum input voltage
45 V
Minimum battery voltage
6.9 V
Currents
Max. continuous module current at 25 °C
20 A
Max. continuous load current at 25 °C
20 A
Excess Temperature Protection
Disconnect load >85 °C
Reconnect load <75 °C
Data for final charging voltage
Depends on set
battery type
Gel – storage
battery (GEL)
Liquid electrolyte (Li)
Float charge
13.9 V / 28.2 V
13.9 V / 27.8 V
Boost charge; for 2:00 h
14.4 V / 28.8 V
14.4 V / 28.8 V
Equalization charging; for 2:00 h
---
14.7 V / 29.4 V