This manual is a component of the system regulator and must be included with 

the regulator when given to a third person.
The Controller is equipped with a low power surge protection. The installer had 

to care for a efficient lightning protection. 

1.3. 

Scope of Application

This manual describes the function and installation of a regulator for photovoltaic (PV) 

systems for charging 12 V or 24 V lead batteries for recreational, residential, business, 

commercial areas and small businesses and telecommunication.
The charge regulator is only suitable for regulating photovoltaic solar modules. Never 

connect another charging source to the charge regulator. This can destroy the regulator 

and / or source. Consult your specialized dealer or installer if other charging sources 

should be used and observe the ”5.1. SOC Calculation” item in this manual.
The regulator is only suitable for the following chargeable 12 V or 24 V battery types:
- Lead storage batteries with liquid electrolytes
- Sealed lead storage batteries; AGM, GEL
The respective battery type must be set on the regulator, see ”6.3. Battery Type Gel / Li”.
Observe the manufacturer’s instructions before connecting the battery.

Important! The regulator is not suited for nickel cadmium, nickel metal 

hydride, lithium ions or other rechargeable or non-rechargeable batteries. 

Such batteries may not be connected to the regulator. Observe the respec-

tive battery’s safety instructions.
The corresponding manufacture’s installation manual must be observed when 

installing the remaining components, e.g. solar module, battery or consumer.
The regulator may only be used for the particular solar applications pro-

vided. Also, observe that the permitted, model-specific, nominal currents 

and voltages are not exceeded. No liability shall be assumed for any non-

compliant usage. Carefully handle the product.

Содержание PR 2020 IP65

Страница 1: ...Operating instructions Solar Charge Controller PR 2020 IP65 Version 2 0 718 573 Z04 11 27 PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA EN...

Страница 2: ...d current 10 4 2 6 Ah Battery charging meter 10 4 2 7 Ah Battery discharging meter 10 4 2 8 Warning deep discharge protection 11 4 2 9 Load disconnection 11 5 Function Overview 11 5 1 SOC Calculation...

Страница 3: ...e in the 12 V system up to 24 V 24 V system up to 48 V Use only well isolated tools Do not use any technical measuring equipment that you know is damaged or defective When installing the power line en...

Страница 4: ...Calculation item in this manual The regulator is only suitable for the following chargeable 12 V or 24 V battery types Lead storage batteries with liquid electrolytes Sealed lead storage batteries AGM...

Страница 5: ...ges or costs that result due to incorrect installation improper operation usage and maintenance or in any manner associated therewith Similarly we assume no responsibility for patent right or other ri...

Страница 6: ...er the external temperature sensor should be used A temperature compensated final charge voltage will extend the batteries lifetime and uses the optimum charge capacity see appendix Do not install the...

Страница 7: ...ent to 12 V 24 V systems does not function properly if this sequence order is not followed An improper sequence order can damage the battery 2 3 Grounding Grounding the regulator is not technically re...

Страница 8: ...off the consumer Open circuit proof during operation without battery or consumer Load output is protected from high module open circuit voltage directly flowing to load side Reverse current protectio...

Страница 9: ...t to voltage control the SOC bar dis play does not appear and the battery voltage value replaces the SOC percentage value Please observe that the accuracy of the regulator s display is not comparable...

Страница 10: ...from the solar module 4 2 5 Load current Displays the current drawn by the load output 4 2 6 Ah Battery charging meter Displays the accumulative sum of recharged Ah since the initial installation or r...

Страница 11: ...s SOC information you always have an accurate overview on the actual battery level Using the SOC the regulator also controls the selection of the charging procedure and the deep discharging protection...

Страница 12: ...rol type Press the left button again to call up the various windows Press the right button to modify settings The display begins to flash Now with the left button select the settings options The setti...

Страница 13: ...reshold cannot be specified accurately An activation delay cannot be set when twilight sets in 6 5 Morning Light Function Setting Analog to night light this function can switch on the load in the morn...

Страница 14: ...Query Each regulator has a serial number that can be queried using this window Press the right button and the SN display begins to flash Now press the left button to display the number The digits are...

Страница 15: ...consumer solar module and battery Reinstall the device If the error reoccurs please contact your specialized dealer Communication error on the external bus 6 pole edge connector Check the 6 pole plug...

Страница 16: ...ulator s permit ted input current has been exceeded Reduce the load current or module power Short circuiting at the load output Remove short circuit disconnect consumer and try to reconnect no module...

Страница 17: ...lt is provided immediately after it is discovered Legal guarantee claims are to be directed to the seller The seller must be informed before legal guarantee claims are processed For processing a legal...

Страница 18: ...Power consumption mA 12 5 mA 12 V 15 8 mA 24 V PWM Frequency 30 Hz Maximum input voltage 45 V Minimum battery voltage 6 9 V Currents Max continuous module current at 25 C 20 A Max continuous load curr...

Страница 19: ...1 7 V 12 4 V resp 23 4 V 24 8 V Equalization charge SOC 40 11 7 V resp 23 4 V 30 day maintenance charge if within 30 days no equalization or boost charge was active Load disconnection SOC Control Volt...

Страница 20: ...Installation wall installation Weight 350 g Housing recyclable plastic housing Dimensions L x B x H 187 x 44 x 96 mm Fastening hole clearance vertical 60 mm horizontal 177 mm Terminals 10 mm AWG 6 St...

Страница 21: ...f charge voltage using the factor 4 mV K Cell If the connection of the sensor to the regulator is interrupted the regulator will automatically use the standard charge voltage If the cable short circui...

Страница 22: ...s at pin 3 and 4 see illustration A plug with screw terminals is included The polarity is ignored Alarm conditions Alarm ON Load disconnected temp sensor short circuit E04 yes no overtemperature insid...

Страница 23: ...23 718 573 11 27...

Страница 24: ...718573...

Отзывы: