Display
Meaning
Cause / Remedy
Load current too high.
The regulator’s permit-
ted consumer current
has been exceeded, the
load output has there-
fore been disconnected.
Reduce the load current using the
consumer output.
Perhaps current spikes are occurring
through the consumer.
Try reconnecting the load.
Module current too
high.
The regulator’s permit-
ted input current has
been exceeded.
Reduce the load current or module
power.
Short-circuiting at the
load output.
Remove short-circuit, disconnect
consumer and try to reconnect.
• no module con-
nected
or
• short circuit in the
module (moon sym-
bol appears during
the day).
Check module connections.
No battery connected or
connection interrupted.
Supply only by solar module. Connect
battery to regulator and check battery
fuse.
Storage battery con-
nected with reverse
polarity.
Disconnect battery and connect to
regulator with correct polarity.