background image

756.409 | Z02 | 16.31

6

2 Safety

2.1 Proper 

usage

The PA Link1 parallel switch box is exclusively intended for use in stationary au-
tonomous power supplies in accordance with these operating instructions. 

The PA Link1 shall only be operated in a permanently installed and closed condi-
tion.

Only specialists are permitted to carry out the installation.

Any other use is regarded as improper use of the device. Examples of improper 
use: 

•  The PA Link1 parallel switch box must never be connected to the public mains 

grid or a generator.

•  It is not permitted to operate the PA Link1 parallel switch box without fitted 

cover of the terminals, without casing, or with a damaged casing.

•  The device may not be installed outdoors.  

•  An autonomous power supply system (including PA Link1 parallel switch box) 

must not be installed, operated or maintained in locations where inflam-
mable gases and vapours can occur, in dusty environments, or in the vicinity 
of solvents (danger of fire and explosion: ensure that the room is adequately 
ventilated).

•  The PA Link1 parallel switch box, inverters and batteries must not be used in 

the vicinity of open fires, flames or sparks.

2.2 Other 

risks

 WARNING

Battery acid!

 

X

Acid splashes on skin or clothing should be immediately treated with soap 
suds and rinsed with plenty of water.

 

X

If acid splashes into the eyes, immediately rinse with plenty of water and seek 
medical advice.

2.3  Behaviour in the case of faults

 DANGER

•  The connected inverters do not appear to function.

•  Parallel switch box, inverter, alternating current cable or battery cable 

are visibly damaged.

•  If there is smoke emission or fluid penetration.

•  If parts are loose!

 

X

In these cases immediately disconnect the inverter from the battery and the 
parallel switch box from the loads.

2.4  Exclusion of liability

The manufacturer can neither monitor compliance with this manual nor the 
conditions and methods during the installation, operation, usage and mainte-
nance of the parallel switch box. Improper installation of the system may result 
in damage to property and, as a consequence, bodily injury.

Therefore, we assume no responsibility or liability for loss, damage or costs 
which result from, or are in any way related to, incorrect installation, improper 
operation, or incorrect use and maintenance.

Similarly, the manufacturer assumes no responsibility for patent right or other 
right infringements of third parties caused by usage of this parallel switch box.

The manufacturer reserves the right to make changes to the product, technical 
data or assembly and operating instructions without prior notice.

 

X

As soon as it is evident that safe operation is no longer possible
(e.g. visible damage), immediately disconnect the inverter from the battery 
and the parallel switch box from the loads.

EN

Содержание PA Link1

Страница 1: ...Installation and operating instructions PA Link1 parallel switch box 756 409 Z02 16 31 EN...

Страница 2: ...3 Behaviour in the case of faults 6 2 4 Exclusion of liability 6 3 Description of the connections 7 4 Installation 7 4 1 Mounting 8 4 2 Connection 9 4 3 Function test 10 4 4 Making changes to the sys...

Страница 3: ...tch box on 115 V or 230 V see table below One stand alone inverter works as a master the others as slaves The PA Link1 has one output for AC consumers AC OUT Example of a possible application A D C B...

Страница 4: ...riants 1 About these instructions These operating instructions are part of the product X Read these operating instructions carefully prior to installation and use X keep them near the product during i...

Страница 5: ...r bodily injury ATTENTION Possible threat of danger Property damage 1 3 3 Notes NOTES Note on easier and safer working habits X Measures for easier and safer working habits 1 3 4 Other symbols and mar...

Страница 6: ...nty of water X If acid splashes into the eyes immediately rinse with plenty of water and seek medical advice 2 3 Behaviour in the case of faults DANGER The connected inverters do not appear to functio...

Страница 7: ...consumer Data input Solarix PI master RJ45 Data input Solarix PI slave 1 3 3 RJ45 Cable output AC OUT consumer Cable input Solarix PI AC master Cable input Solarix PI AC slave 1 3 4 Installation Examp...

Страница 8: ...cm above and below to allow free air circu lation Enough clearance for the type plate to be visible on the installed device 4 1 2 Mounting the PA Link1 parallel switch box X Unscrew 2 screws 1 on the...

Страница 9: ...ntry specific regulations In the event that due to local regulations or the AC consumers grounding is required X Carry grounding out following the adjacent diagram if TN net is permit ted X Tighten th...

Страница 10: ...electric shock X Before connecting the inverters make sure that no load is switched on and all the inverter rotary switches are set at Off X The cables pre fitted to the inverters must not be extende...

Страница 11: ...lel switch box X Connect the new master or slave as described in Section 4 2 4 4 2 Using a slave as the master If the master fails a slave can be used as the new master X Make sure that no loads are c...

Страница 12: ...eight 0 8 kg Connectable devices Maximum of 4 stand alone inverters of the same type and variant Solarix PI 500 12 60 L60 Solarix PI 550 24 60 L60 Solarix PI 1100 24 60 L60 Solarix PI 1500 48 60 L60 C...

Страница 13: ...y cable X Connect the power cable only after completion of all work X Ensure that the data cable is inserted properly X If LED does not light up replace the data cable X If LED does not light up repla...

Страница 14: ...mages are excluded unless liability is obligatory by law They will help you with all is sues you may have Steca Elektronik GmbH Mammostrasse 1 87700 Memmingen Germany Fon 49 8331 8558 833 Fax 49 8331...

Страница 15: ......

Отзывы: