Installation and operating instructions

PA Link1 parallel switch box

756.409 | Z02 | 16.31

EN

Содержание PA Link1

Страница 1: ...Installation and operating instructions PA Link1 parallel switch box 756 409 Z02 16 31 EN...

Страница 2: ...3 Behaviour in the case of faults 6 2 4 Exclusion of liability 6 3 Description of the connections 7 4 Installation 7 4 1 Mounting 8 4 2 Connection 9 4 3 Function test 10 4 4 Making changes to the sys...

Страница 3: ...tch box on 115 V or 230 V see table below One stand alone inverter works as a master the others as slaves The PA Link1 has one output for AC consumers AC OUT Example of a possible application A D C B...

Страница 4: ...riants 1 About these instructions These operating instructions are part of the product X Read these operating instructions carefully prior to installation and use X keep them near the product during i...

Страница 5: ...r bodily injury ATTENTION Possible threat of danger Property damage 1 3 3 Notes NOTES Note on easier and safer working habits X Measures for easier and safer working habits 1 3 4 Other symbols and mar...

Страница 6: ...nty of water X If acid splashes into the eyes immediately rinse with plenty of water and seek medical advice 2 3 Behaviour in the case of faults DANGER The connected inverters do not appear to functio...

Страница 7: ...consumer Data input Solarix PI master RJ45 Data input Solarix PI slave 1 3 3 RJ45 Cable output AC OUT consumer Cable input Solarix PI AC master Cable input Solarix PI AC slave 1 3 4 Installation Examp...

Страница 8: ...cm above and below to allow free air circu lation Enough clearance for the type plate to be visible on the installed device 4 1 2 Mounting the PA Link1 parallel switch box X Unscrew 2 screws 1 on the...

Страница 9: ...ntry specific regulations In the event that due to local regulations or the AC consumers grounding is required X Carry grounding out following the adjacent diagram if TN net is permit ted X Tighten th...

Страница 10: ...electric shock X Before connecting the inverters make sure that no load is switched on and all the inverter rotary switches are set at Off X The cables pre fitted to the inverters must not be extende...

Страница 11: ...lel switch box X Connect the new master or slave as described in Section 4 2 4 4 2 Using a slave as the master If the master fails a slave can be used as the new master X Make sure that no loads are c...

Страница 12: ...eight 0 8 kg Connectable devices Maximum of 4 stand alone inverters of the same type and variant Solarix PI 500 12 60 L60 Solarix PI 550 24 60 L60 Solarix PI 1100 24 60 L60 Solarix PI 1500 48 60 L60 C...

Страница 13: ...y cable X Connect the power cable only after completion of all work X Ensure that the data cable is inserted properly X If LED does not light up replace the data cable X If LED does not light up repla...

Страница 14: ...mages are excluded unless liability is obligatory by law They will help you with all is sues you may have Steca Elektronik GmbH Mammostrasse 1 87700 Memmingen Germany Fon 49 8331 8558 833 Fax 49 8331...