![Stec M16SD2S 100U Series Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/stec/m16sd2s-100u-series/m16sd2s-100u-series_product-manual_1369105069.webp)
MACH16
S
LIM
L
ITE
3Gbps
SATA
S
TANDARD
S
OLID
-S
TATE
D
RIVE
P
ART
N
UMBER
:
M16SD2S(3)-
XXX
U(T)(X)-XXX
D
OCUMENT
N
UMBER
:
61000-07132-311
R
EVISION
N
UMBER
:
3.11
R
EVISION
D
ATE
:
01/15/2013
69
V
10:9 These bits indicate how Device 1 determined the
device number:
00 = Reserved
01 = A jumper was used.
10 = The CSEL signal was used.
11 = Some other method was used or the method is
unknown.
8 Shall be set to one.
P
7:0 Device 0 Hardware Reset Result. Device 1 shall clear these bits
to zero. Device 0 shall set these bits as follows:
7 Reserved
F
6 0 = Device 0 does not respond when Device 1 is
selected.
1 = Device 0 responds when Device 1 is selected.
V
5 0 = Device 0 did not detect the assertion of DASP-.
1 = Device 0 detected the assertion of DASP-.
V
4 0 = Device 0 did not detect the assertion of PDIAG-.
1 = Device 0 detected the assertion of PDIAG-.
V
3 0 = Device 0 failed diagnostics.
1 = Device 0 passed diagnostics.
V
2:1 These bits indicate how Device 0 determined the
device number:
00 = Reserved
01 = A jumper was used.
10 = The CSEL signal was used.
11 = Some other method was used or the method is
unknown.
F
0 Shall be set to one.
94
O
Current AAM Value
B
F
15:8
Vendor’s recommended AAM value.
B
V
7:0 Current AAM value.
95
O
B
F
Stream Minimum Request Size
96
O
B
V
Streaming Transfer Time-DMA
97
O
B
V
Streaming Access Latency-DMA and PIO