![Stec M16SD2S 100U Series Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/stec/m16sd2s-100u-series/m16sd2s-100u-series_product-manual_1369105113.webp)
MACH16
S
LIM
L
ITE
3Gbps
SATA
S
TANDARD
S
OLID
-S
TATE
D
RIVE
P
ART
N
UMBER
:
M16SD2S(3)-
XXX
U(T)(X)-XXX
D
OCUMENT
N
UMBER
:
61000-07132-311
R
EVISION
N
UMBER
:
3.11
R
EVISION
D
ATE
:
01/15/2013
113
R
ADIO
F
REQUENCY
I
MMUNITY
R
EQUIREMENTS
This specification is targeted as part of the design for quality and reliability expectations and is not part of
the regulatory requirements. The SSDs meet the following radio frequency immunity requirements:
3 V/m over frequency range of 80 MHz to 1 GHz
The signal will be amplitude modulated with a 1KHz sine wave to a depth of 80%
Failure Criteria: More than 10% throughput degradation
EMI
T
ESTING
STEC, Inc. conducts EMI testing at approved test facilities, but recommends that customers also conduct
EMI testing at their own approved EMI test facilities to ensure correlation with EMI testing of their end
systems.
V
ERIFICATION
T
ESTING
Verification testing will be performed by the customer’s Compliance Peripheral Group.
E
LECTROSTATIC
D
ISCHARGE
(ESD)
The SSD will meet the ESD limits specified in the 61000-4-
2 guidelines and the customer’s enhanced
ESD procedure. The specification will determine whether the contact or air discharge method should be
used. Performance degradation is defined as a decreased throughput rate. No data errors are allowed.
Table 31 lists the ESD requirements and performance criteria.
Table 31: ESD Requirements
C
LIMATIC
C
ONDITIONS
V
ALUE
Ambient Temperature
15° to 35°C
Relative Humidity
30% to 60%
Atmospheric Pressure
86kPa (860 millibar) to 106kPa (1,060 millibar)
D
ISCHARGE
C
ONDITIONS
V
OLTAGE
L
EVEL
D
ISCHARGE
T
YPE
P
ERFORMANCE
C
RITERIA
±4kV
Contact
The apparatus will continue to operate as intended,
i.e., normal unit operation with no degradation of
performance.
±8kV
Air