6. MAINTENANCE & TROUBLESHOOTING
6.1 VISUAL INSPECTION
Inspect the inverter and the cables for visible damage and pay attention to the operating status display of
the inverter.
Before maintenance, you must disconnect AC and DC to avoid risk any shock.
In case of any damage, notify your installer. Repair may only be carried out by authorised eletricians.
PLEASE CARRY OUT VISUAL INSPECTION AT LEAST ONCE OR TWICE A YEAR.
6.1.1 CLEANING THE INVERTER EXTERNALLY
Only use completely dry cloth/tissue to clean the inverter.
Only the exterior of the inverter should be cleaned.
Use a soft and dry brush to remove dust from the fan cover and from the top side of the inverter on a
regular basis.
LETHAL VOLTAGES ARE STILL PRESENT IN THE TERMINALS AND CABLES OF THE INVERTER EVEN
AFTER THE INVERTER HAS BEEN SWITCHED OFF AND DISCONNECTED.
6.1.2 BATTERY MAINTENANCE
Batteries should not be discharged more than 50% of their capacity on a regular basis. Under extreme
conditions (such as a severe storm or a long utility outage), cycling to a discharge level of 80% is
acceptable.
Totally discharging a battery may result in permanent damage and reduced life. Our PCUs limit the depth
of discharge to 60% to prolong the life of the batteries and save on your battery costs in the long run.
6.1.3 PV MAINTENANCE
PV Panel surface should be clean.
PV Panel should be replaced in case of any damage of upper layer (Non reflective layer).
PV Panel should be checked regularly to ensure that it is receiving maximum sunlight possible.
PRESS KEY ENTER WHILE IN NORMAL PARAMETER DISPLAY TO SEE THE FAULT INDICATION IN
PCU.
6.2 TROUBLESHOOTING
FAULT * 0 (SYSTEM TRIP) : This fault may occur due to different reasons of accompanied fault or may be
due to internal issues in PCU.
REMEDY:
Check the other faults indicated with FAULT * 0 and refer their remedies. Immediate consultation with a
service expert is required.
IN CASE OF ANY OTHER REASON CONTACT TO SERVICE ENGINEER.
FAULT * 1 (INVERTER OUTPUT UNDER VOLTAGE/INVERTER OUTPUT BAD : This fault may occur due to
improper output of inverter or due to loose connections.
REMEDY:
Check all connections of your PCU.
IN CASE OF ANY OTHER REASON CONTACT TO SERVICE ENGINEER.