Change the Mirror Configuration settings
Use the Mirror Configuration screen to mirror traffic from any source port to a target
port.
You can access the screen by clicking
Configuration
>
Mirroring
.
Menu option
Description
Port
The logical port for the settings is contained in the same row.
Mode
Select mirror mode.
Rx only: Frames received on this port are mirrored on the
mirror port. Frames transmitted are not mirrored.
Tx only: Frames transmitted on this port are mirrored on the
mirror port. Frames received are not mirrored.
Disabled: Neither frames transmitted nor frames received are
mirrored.
Enabled: Frames received and frames transmitted are
mirrored on the mirror port.
Note:
For a given port, a frame is only transmitted once. It
is therefore not possible to mirror Tx frames on the mirror
port. Because of this, the mode for the selected mirror port is
limited to Disabled or Rx only.
1. On the main screen of the Web management UI, click
Configuration
>
Mirroring
.
2. Select the destination port that all mirrored traffic is sent to.
3. Set the mirror mode on and of the source ports that will be mirrored.
4. To save your settings, click
Save
.
To restore the previous settings, click
Reset
.
Change the UPnP settings
Use The UPnP Configuration page to setup UPnP. Universal Plug and Play is a set of
protocols that allows devices to deploy easily.
You can access the screen by clicking
Configuration
>
UPnP
.