ALTERNATING CURRENT (AC) CONNECTION
BE SURE ANY ELECTRIC DEVICES ARE TURNED OFF BEFORE PLUGGING THEM IN
NOTICE
Be sure all electric devices including the lines and plug connections are in good condition before
connecting to the generator.
Be sure the total load is within generator rated output.
Be sure the receptacle load current is within receptacle rated current.
TIP:
Make sure to ground (Earth) the generator. When the electric device is earthed, the generator
must always be earthed.
1. Start the engine
2. Turn the ECS to ON
3. Plug in to the AC receptacle
4. Make sure the AC pilot light is on
5. Turn on any electric devices
TIP:
The ECS must be turned to OFF to increase engine speed to rated rpm. If the generator is
connected to multiple loads or electricity consumers, remember to first connect the one with the
highest starting current, then lastly connect the one with the lowest starting current.
BATTERY CHARGING
The generator DC rated voltage is 12V
Start the engine first and then connect the generator to the battery for charging.
Before starting to charge the battery, make sure that the DC protector is turned on.
1. Start the engine.
2. Connect the red battery charger lead to the positive (+) battery terminal.
3. Connect the black battery charger lead to the negative (-) battery.
4. Turn the ECS to OFF to start battery charge.
11