manualshive.com logo in svg
background image

Page No 1

Form ZCE494
Date 2006Feb22/A

Model 

5263

Short Needle Scaler

IMPORTANT

Read these instructions carefully before installing, operating, servicing or repairing this
tool. Keep these instructions in a safe accessible place.

– Always wear safety goggles.

– Prolonged exposure to vibration may cause injury.

– Read all instructions before using this

 

tool. All operators must be fully

trained in its use and aware of these safety rules.

– Do not exceed the maximum working air pressure.

– Use personal protection equipment as recommended.

– Some dust created by power sanding, sawing, grinding, drilling, and

other construction activities contains chemicals known to cause cancer,
birth defects and other reproductive harm.

– Use compressed air only at the recommended conditions.

– If the tool appears to malfunction remove from use

 

immediately and

arrange for service and repair. If it is not practical to remove tool from
service, then shut off the air supply to the tool and write or have written
a warning note and attach it to the tool.

– If tool is to be used with a balancer or other suspension device, ensure

that the tool is firmly attached to the suspension support device.

– When operating the tool, always keep the body and particularly the hands

away from the working attachment fixed to the tool.

– The tool is not electrically insulated. Never use the tool if there is any

chance of coming into contact with live electricity.

– Always when using the tool, adopt a firm footing and/or position and grip

the tool sufficiently only to overcome any reaction forces that may result
from the tool doing work. Do not overgrip.

– Use only correct spare parts for maintenance and repair. Do not improvise

or make temporary repairs. Major servicing and repairs should only be
carried out by persons trained to do so.

– Do not lock, tape, wire, etc. the ‘On/Off’ valve in ‘On’ position. The throttle

trigger/lever, etc. must always be free to return to the ‘Off’
position when released.

– Always shut off the air supply to the tool and press the ‘On/

Off’ valve to exhaust the air from the feed hose before
fitting, removing or adjusting the working attachment
fitted to the tool.

– Before using the tool, make sure that a shut off device has

been fitted to the supply line and the position is known and
easily accessible so that the air supply to the tool can be
shut off in an emergency.

– Check hose and fittings regularly for wear.

– Take care against entanglement of the moving parts of

the tool with clothing, hair, ties, cleaning rags, rings,
jewelry, watches, bracelets, etc. This could cause the body
or parts of the body to be drawn towards and in contact with
the moving parts of the tool and could be very dangerous.

WARNING

Always Read Instructions
Before Using Power Tools

Always Wear Safety Goggles

Wear Hearing Protection

Avoid Prolonged Exposure
To Vibration

SAFETY MESSAGES

Personal 

Safety Equipment

Use - Safety Glasses

YES

Use - Safety Gloves

YES

Use - Safety Boots

Use - Breathing Masks

YES

Use - Ear Protectors

YES

Operator Instructions

Includes:

Safety Rules
Work Stations
Foreseen Use
Putting Into Service
Operating
Dismantling and Assembly.

Safety rules when using a 

5263 

Needle Scaler

– It is expected that users will adopt safe working practices and observe all

local, regional or country legal requirements when installing, using or
maintaining the tool.

– Take care that the exhaust air does not point towards any other person

or material or substance that could be contaminated by oil droplets. When
first lubricating a tool or if the tool exhaust has a high oil content, do not
allow the exhaust air to come near very hot surfaces or flames.

– Never lay the tool down until the working attachment has stopped moving.

– When the tool is not in use, shut off the air supply and press throttle trigger/

lever to drain the supply line. If the tool is not to be used for a period of
time, first lubricate, disconnect from air supply and store in a dry average
room temperature environment.

– If the tool is passed from one user to a new or inexperienced user, make

sure these instructions are available to be passed with the tool.

– Do not remove any manufacturer fitted safety devices where fitted, i.e.,

wheel guards, safety trigger, speed governors, etc.

– Wherever possible, secure workpiece with clamps, a vise, etc. to make it

rigid so it does not move during the work operation. Keep good balance
at all times. Do not stretch or overreach.

– Try to match the tool to the work operation. Do not use a tool that is too

light or heavy for the work operation. If in doubt, seek advice.

– In general terms, this tool is not suitable for underwater use or use in

explosive environments - seek advice from manufacturer.

– Try to make sure that the work area is clear to enable the work task to be

performed safely. If practical and possible, try to clear unnecessary
obstructions before starting work.

– Always use air hose and couplings with minimum working pressure ratings

at least 1 1/2 times the maximum working pressure rating of the tool.

Содержание 5263

Страница 1: ...ngs regularly for wear Take care against entanglement of the moving parts of the tool with clothing hair ties cleaning rags rings jewelry watches bracelets etc Thiscouldcausethebody orpartsofthebodytobedrawntowardsandincontactwith the moving parts of the tool and could be very dangerous WARNING Always Read Instructions Before Using Power Tools Always Wear Safety Goggles Wear Hearing Protection Avo...

Страница 2: ... be lubricated by shutting off the air supply to the tool depressurizing the line by pressing the trigger on the tool Disconnect the air line and pour into the hose adaptor a teaspoonful 5ml of a suitable pneumatic motor lubricating oil preferably incorporating a rust inhibitor Reconnect tool to air supply and run tool slowly for a few seconds to allow air to circulate the oil If tool is used freq...

Страница 3: ...river 16 2259 Needle Set of 12 17 505523 Needle Holder 18 505524 Spring 19 505525 Needle Tube 505488 Warning Label Not Shown Order Quantity As Required 5263 Short Needle Scaler Ret No Part No Description 1 505510 Backhead 2 505511 O Ring 3 505512 Valve 5 505513 Spring 6 505514 Valve Cap 7 505515 Lover 8 505516 Pin 9 505517 Rubber Cushion ...

Страница 4: ... Meters Sec2 Test Method Tested in accordance with ISO standards 8662 Part 1 Product Type RPM Short Needle Scaler 4 000 Cycles Per min ModelNo Nos Serial No 5263 Other Data Piston Diameter 18 x 14 x 47mm Number Of Needles 12 Needle Diameter 3mm Needle Length 1 4 18NPT Overall Length 125mm Operation Specification Average Air Consumption 6 cfm 43 scfm Stroke 0 62 16mm Air Inlet Thread 1 4 18NPT Over...

Страница 5: ...This pdf incorporates the following model numbers 5263 ...

Отзывы: