SECTION 6
PROPANE SYSTEM STARCRAFT TOWABLE
1. Check that ALL fittings are tight.
2. Check that ALL connections are tested
with a propane leak detector (or soapy
water) solution.
3. Open the main valve slowly to avoid a fast
rush of propane to the excess flow valve
causing propane freeze up. If you
experience a propane “freeze-up,” close
the main valve and wait at least fifteen
(15) minutes before trying again. Refer to
the regulator manufacturer’s operator
manual.
4. Listen carefully - a “hissing” sound longer
than one second may indicate a propane
leak. If you feel there may be a leak
present, close the valve and contact your
dealer or qualified propane technician for
repair assistance.
Replace all protective covers and caps on the
propane system after filling. Make sure the
valve is closed and the compartment door is
securely latched.
Maintenance
Propane gas is normally non-corrosive - you
need not worry about the inside of your
container. However, the outside should be
kept free from rust by a periodic coat of paint
in a light reflective color. Rust, scratches
and/or dents can affect the safety of the
cylinder. Inspect the cylinder at regular
intervals. If there is a problem, have it
evaluated by a qualified technician and
discard it. DOT requires that a visual
inspection be made prior to each filling.
Any cylinder that has been exposed to fire,
leaks or seems damaged should not be
refilled.
Do not attempt to repair any containers,
container valves, regulator or appliances by
yourself. Use only trained certified propane
gas service technicians to perform repairs.
Propane cylinder recertification
If you have an older RV you should know that,
according to Federal law, DOT cylinders may
only be used for 12 years after their
manufacture date (the number of years for
certification may vary in your area).
After that, the cylinders must be "recertified"
which provides another five years of use. The
cylinders can be recertified every five years
thereafter. Federal DOT (Department of
Transportation) regulations require periodic
inspections and re-qualifications of the
propane cylinders. DO NOT USE damaged or
rusted containers.
Verify with your local propane dealer that all
required inspections and certifications have
been completed on the propane cylinder
within the correct time period before refilling
the cylinder.
Have the LP system checked for leakage
each time a cylinder is refilled or after any part
of the propane system has been
disconnected.
P
ROPANE
R
EGULATOR
Single stage regulator
Some models are equipped with a single
stage regulator.
Two stage regulator
The two-stage regulator has the only moving
components in the propane system. Its sole
function is to reduce the pressure from the
propane containers to a safe and consistent
low operating pressure. The first stage
reduces the container pressure to 10-13 lbs.
The second stage reduces the 10-13 lbs. of
pressure further to an operating pressure of
11” W.C. (water column) or 6.35 oz. of outlet
pressure to your appliances.
Propane regulators must always be
installed with the regulator vent facing
downward. Regulators that are not located
in baggage compartments have been
equipped with a protective cover. Make
sure the regulator vent faces downward
and (if applicable) the cover is in place to
minimize vent blockage that could result in
excessive gas pressure causing fire or
explosion.
6 - 6
Содержание Travel Star
Страница 1: ...OWNER S MANUAL 2012 P N 0221643 2012 TRAVEL TRAILERS FIFTH WHEELS TRAVEL STAR...
Страница 40: ...SECTION 4 TOWING HANDLING STARCRAFT TOWABLE 4 8 THIS PAGE IS INTENTIONALLY BLANK...
Страница 56: ...SECTION 6 PROPANE SYSTEM STARCRAFT TOWABLE 6 10 THIS PAGE IS INTENTIONALLY BLANK...
Страница 76: ...SECTION 9 SLIDEOUT SYSTEM TOWABLE 9 4 THIS PAGE IS INTENTIONALLY BLANK...
Страница 94: ...SECTION 12 SPECIFICATIONS TOWABLE WHEEL LUG TORQUE CHART 12 2...