Technical Primer - Aurora
3
Technical Data about the Product
• Suitable for all vehicles complying with IEC 62196-2.
• Configurable Output power setting possibility
• MID certified meter for verifiable output power measurements
• Charge via scanning QR Code and RFID swiping card.
• The charger supports the OCPP 1.6J communication protocol i.e., the charger can communicate
to the data service platform and management platform (Cloud platform) of OCPP 1.6J.
• The charger can work normally when used in an outdoor environment IP55(Case C) and IP54(Case
B), IK10..
• The device has the following protection feature
–
Lightning protection
–
Overload protection
–
Leakage protection
–
Over-voltage protection
–
Under-voltage protection
–
PE (Protective Earth) detection.
3.1
Technical Specifications
3.1.1
Mains Supply Parameters
Recommended cable diameters
at the input (Minimum)
UL-AWM1015 9AWG
(outside diameter 13 mm-15 mm)
Nominal line input voltage
400V AC (+/- 10%)
Limits of input power
3-phase: 16 A max per phase
Nominal frequency
50/60 Hz
Connection terminals
Pin terminal:E6012-BLACK,KST*3
Round terminal:RVL5-4,KST*3
Ground terminal:AVK16RD*1
Grounding
TN system (PE wire)
TT system (independently installed ground electrode)
Main MCB
400 V AC, 40A, 50/60 Hz, Tripping characteristics C
Stand-by consumption
Less than 10W