8.5
Not fully charged, report that the battery is full or the connection is
unsuccessful
The indicator light is green but there is no current.
General working principle
When the charger is normal operation and the connection is normal, the switch S1 is switched
from the +12V connection state to the PWM connection state, and the power supply control device
issues a PWM signal. At this time, if the vehicle S2 is closed, the voltage of "Monitoring Point 1"
changes from 9V to 6V. At this time, the power supply control device closes the contactors K1 and
K2 to make the AC power supply circuit conductive.
Troubleshooting tips
1. It is recommended that the customer recharge and check whether it is an accidental fault.
2. If the fault still exists, it is recommended to drive the vehicle to an external charger or a Auto-
mobile Sales Service shop charger for trial charging.
3. If there is another failure, the vehicle is judged to be faulty. It is recommended that the customer
go to the 4S shop to check the vehicle.
4. Try to charge after replacing the mainboard.