T R O U B L E S H O OT I N G
If you believe there is a problem please check the points below.
If the problem cannot be rectified after carrying out the checks listed, switch off the unit at
the mains electricity supply spur (adjacent to the lift), press the emergency stop button and
contact your local service branch
Basic fault finding (both models)
If the lift will not operate, check the following points before contacting your service
company.
•
Ensure the emergency stop button on the car controls is not pressed down.
•
Check that moving safety devices are not activated or stuck in, check platform edges
and top carriage safety edges.
•
Ensure that the lift is not isolated via a key-switch; this will result in the call buttons not
being illuminated. (check landing call stations and remote locking devices, changing
the position of any one key will turn the lift off or on).
•
Check the gates, where fitted, are fully closed.
•
Check there are no obstructions on or around the ramp.
•
Check there are no obstructions on or around the lift safety bellows.
•
Check the power supply to the lift is on.
For Lowriser 2.0
For Lowriser 2.0
For Lowriser 2.0
For Lowriser 2.0
Ensure that the Residual Current Device (RCD) switch & Miniature Circuit Breaker (MCB) are
both ON. Both are located within the control box. Then proceed as follows:
•
Ensure mains supply is OFF.
•
Unlock control box using special key.
•
RCD and MCB are situated at the top/back of the cabinet.
•
Switch both ON if tripped.
•
Close and lock Gate.
•
Turn mains supply back on.