LO W R I S E R 2 . 0 - E M E R G E N C Y
Emergency Lowering – Using
Pump Lowering Valve
Using the pump box release key
(provided) open the enclosure door.
Twist key approximately ¼ turn and pull
the door open.
Pull the red solenoid knob and the lift
will lower towards the ground, releasing
the knob will stop the platform descent.
When the platform has reached the
lower floor level the gates can be
opened manually.
WARNING!
WARNING!
WARNING!
WARNING!
The safety devices will not
work when manually lowering the lift.
Ensure that any obstructions are
removed and that the user is aware of
the process.
Manual Release of Gates
WARNING!
WARNING!
WARNING!
WARNING!
Ensure that the lift is at the lower level before
manually opening the Gate.
Remove the rubber grommet on the gate lock infill.
Align and insert the triangular gate release key provided.
Twist approximately ¼ turn and pull the gate open.
Replace the grommet on completion.
Note: It is recommended you keep the gate release key in a convenient place in case of an