LO W R I S E R 2 . 0 - E M E R G E N C Y
Raising the alarm
In order for a trapped person to be able to call for help with an operating failure; the lift
has been equipped with an alarm facility. When the alarm button is depressed the
emergency signal is sounded. The alarm is powered by the battery backed facility.
Emergency in-car lowering
In the event of a power failure which
results in the user being trapped
between floors, the lift can be lowered
to the floor that is the nominated exit
point for the building. Emergency
lowering is achieved by pressing the
down direction button which will be
illuminated at point of power failure.
In-car emergency lowering –
power failure
The lift incorporates a facility that will
allow the lift to be lowered to the ground floor in the event of a power failure.
1. In the event of a power failure, the lower Green, directional arrow will illuminate.
2. At this point the operator can press and hold the Green Down Arrow to allow the lift to
travel to the ground floor.
Note: In the unlikely event of this feature not working the lift can be lowered using the
emergency lowering valve on the pump unit, which is contained in an enclosure.
Manual lowering
In the event of a mains power and battery failure, the lift can be lowered to the ground
floor by operating the emergency-lowering solenoid valve located in the control box.
WARNING! Ensure that the control box is isolated from the mains supply before opening.
WARNING! Ensure that the control box is isolated from the mains supply before opening.
WARNING! Ensure that the control box is isolated from the mains supply before opening.
WARNING! Ensure that the control box is isolated from the mains supply before opening.
After using the emergency lowering valve, shut and lock the control box before
After using the emergency lowering valve, shut and lock the control box before
After using the emergency lowering valve, shut and lock the control box before
After using the emergency lowering valve, shut and lock the control box before
reconnecting the mains supply.
reconnecting the mains supply.
reconnecting the mains supply.
reconnecting the mains supply.
FOR USE BY TRAINED AND AUTHORISED PERSONNEL ONLY
Opening of doors introduces risks. Emergency unlocking should be undertaken only
in exceptional circumstances and by suitably trained and authorised persons.
To be used only in an emergency by trained and authorised persons who have had
instructions. It is dangerous for any other person to attempt this procedure.
!!!!