TARA EXPLODED VIEW

14

1.

COMBUSTION CHAMBER -

F01087AXX

2.

LEG (LONG)

- B00007BZZ

3.

FRONT PANEL

- B00257JXX

4.

SIDE PANEL

- B00211BZZ

5.

5” DRAFT REGULATOR

- F00553AXX

6.

CONTROL BRACKET ASSY

- F01088AXX

7.

VENT CASTING 

- Q00762AXX

8.

TOBY OIL VALVE

- V00569AXX

9.

HOB

- B00209AZZ

10. HOB BLANKING PLATE 

- B00210AZZ

11. FRONT DOOR

- B00258CZZ

12. DOOR GLASS CLIP 

- F00003AXX

13. DOOR HANDLE AXLE 

- V00022BXX

14. DOOR HANDLE (LONG)

- U00009AXX

15. GLASS WINDOW

- T00009BXX

16. HINGE

- U00153AXX

17. SPIN VALVE

- B00012AXX

18. SPACER

- V00489AXX

19. DOOR LATCH

- V00023AXX

20. CONTROL ROD 

- V01001AXX

21. CONTROL KNOB 

- U00086AXX

22. P-CLIP (RS543-361) 

- V00111AXX

23. INTERNAL BACK BAFFLE ASSY

- F01091AXX

24. INTERNAL LH BRACKET

- F01092AXX

25. INTERNAL RH BAFFLE 

- F01093AXX

26. HOLD BRACKET

- F01142AXX

27. BOTTOM SHIELD SUPPORT BKT

- F01095AXX

28. SPACER 

- V00033AXX

29. AIR WASH KNOB

- U00077AXX

30. TERRY CLIP 

- W00921AXX

31. ISOLATING TRANSFORMER

- G00506AXX

32. STRAIN RELIEF CABLE GLAND

- V00961AXX

33. TRANSFORMER COVER

- F01134AXX

34. ILLUMINATED PUSH SWITCH 

- G00504AXX

35. FITTING STRAIGHT 1/4” BSP X 10MM 

W00908AXX

36. MOULDED PLUG

- G00047AXX

37. WIRE LOOM

- G00505AXX

38. BADGE

- V00730BXX

39. SERIAL NUMBER PLATE 

- N00234BXX

40. COVER 

- F01197AXX

41. PULL CONTROL ROD 

- V01023AXX

42. EXCESS AIR DAMPER

- F01315AXX

43. 8” BURN POT

- D00358AXX

44. FLAME SPREADER

- D00356AXX

45. FLAME DEFLECTOR RING 

- D00461AXX

46. SCRUBBER 

- V00473BXX

47. M12 X 1MM CAP

- V00977AXX

48. OIL FEED PIPE

- V01003AXX

49. FITTING STRAIGHT 1/4” BSP 8MM 

- W00906AXX

50. IGNITION PROBE C/W LEADS 

- G00450AXX

51. ADAPTOR

- V00864AXX

52. 9MM OD WASHER 

- V00978AXX

53. OPEN GROMMET

- V01035AXX

54. COVER

- F01089AXX

55. ASHTRAY FRONT

- B00259AZZ

56. CERAMIC LOGS

- V01044AXX

Содержание Tara Mk3

Страница 1: ...nce is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervised at all times and should not be allowed to touch the hot work...

Страница 2: ...lues or Chimneys 9 16 Use of External Flues 9 17 Flue Termination Height 10 18 Flue Stabilizer 10 19 Ventilation Combustion Air Requirement 10 20 Installation Assembly 11 21 Fire Log Setup 11 22 Commi...

Страница 3: ...oat use disposable protection Installation should be carried out in a well ventilated area Any alterations to this appliance that are not approved in writing by Waterford Stanley will render the guara...

Страница 4: ...at the maximum permitted oil flow rate This appliance has been tested and approved to EN1 flued oil stoves with vaporizing burners Appliance Class 2b All technical data are taken under laboratory con...

Страница 5: ...12 inches to the front Note The hearth must be level stable and capable of supporting the stove ELECTRICAL SUPPLY All wiring external to the appliance must conform to the current B S 7671 UK B S 7462...

Страница 6: ...rewed joints must only be made with taper threads complying to B S 1740 Part 1 1971 Jointing materials must be of types intended for use with oil fuel Special petroleum resisting compounds and PTFE ta...

Страница 7: ...er and control valve A suitable shut off valve should be fitted near the stove and be accessible at all times NOTE Fuel to the appliance should be gravity fed only 7 These requirements are in accordan...

Страница 8: ...do so could result in loss in performance of the stove WARNING Only operate this appliance if connected to a properly installed flue system This stove must be connected to a 125mm 5 diam eter flue sys...

Страница 9: ...RNAL FLUES OR CHIMNEYS When connecting the stove to an existing chimney or internal flue the flue system must adhere to all the fol lowing requirements See Fig 11 1 The horizontal flue section exiting...

Страница 10: ...upply to the flue whenever the flue s negative pressure reaches its upper limit and so pre vents the negative pressure in the stove rising above its optimum level The flue stabiliser should be ad just...

Страница 11: ...Level the stove in all directions using the level ling screws on the stove legs 5 Connect the fuel line to the oil control valve and reset the control valve trigger as shown in Fig 17 6 Check all joi...

Страница 12: ...perature i e at maximum setting adjust the draught regulator until the desired flame pattern is achieved 5 Using the flue sampling point See Fig 19 check that the Bacharach smoke number is not greater...

Страница 13: ...op of oil falls into the vessel 3 Measure the oil flow for 5 minutes Consult the Technical Data section for the correct rate 4 Turn the control valve to 1 and repeat the above procedure 5 If either of...

Страница 14: ...X 26 HOLD BRACKET F01142AXX 27 BOTTOM SHIELD SUPPORT BKT F01095AXX 28 SPACER V00033AXX 29 AIR WASH KNOB U00077AXX 30 TERRY CLIP W00921AXX 31 ISOLATING TRANSFORMER G00506AXX 32 STRAIN RELIEF CABLE GLAN...

Страница 15: ...ustible materials and soft furnishings well away from the stove See Clearance to Combustibles section WARNING Unauthorised modification of the stove will void the product warranty Do not tamper with t...

Страница 16: ...es on setting no 2 the control lever can be adjusted to setting no 4 The flame should be allowed to sta bilise at setting no 4 for another 10 minutes prior to adjusting the control to setting No 6 Max...

Страница 17: ...t the draught stabiliser as it will effect the performance of the stove CO ALARM Waterford Stanley recommend the fitting of a CO Alarm in the same room as the appliance Further guidance on the install...

Страница 18: ...ly with a soapy damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel 3 Use only products recommended by t...

Страница 19: ...locked Bleed fuel line Excessive flame noise Incorrect chimney draught Check joint seals increase height of chimney adjust draught regulator Incorrect fuel input rate Check fuel input rates adjust if...