FAULT FINDING
If the stove exhibits any of the following conditions, call your commissioning engineer.
SYMPTOM
POSSIBLE CAUSES
REMEDY
Stove will not light
No electrical supply to the
Check Plug Top Fuse or connec-
stove
tor block fuse.
No Oil in tank
Fill Tank
Manual or fire valves off
Open or reset valves.
Check for cause of over
temperature if necessary.
Control valve trigger down (off)
Reset trigger.
Thermal fuse in transformer blown
Replace transformer.
Oil feed line filter blocked
Free oil filter
Fuel line air locked
Bleed fuel line
Excessive flame noise
Incorrect chimney draught
Check joint seals, increase
height of chimney adjust
draught regulator
Incorrect fuel input rate
Check fuel input rates,
adjust if necessary
Dirty or Unstable flame
Incorrect flue draught
Check joint seals, increase
height of chimney, adjust
draught regulator
Incorrect fuel input rate
Check fuel input rates,
adjust if necessary
Down draughting
Fit suitable cowl
Incorrect fuel bed set-up
Adjust coal positions
Door glass sooting up excessively
Incorrect flue draught
Check joint seals, increase
height of chimney, adjust
draught regulator
Poor door seal
Replace door seal
Fuel input rate too high
Check fuel input rates,
adjust if necessary
19