13
NOTE: It is imperative that the stove is not rated
above the maximum flow rate as to do so will
raise the operating temperature of the stove
which could damage the control equipment or
the stove itself.
Low Rate Adjustment
High Rate
Adjustment
Fig.21
2. Place the collection vessel beneath the inlet pipe
to catch the oil. Turn the control valve to 6
and start the stopwatch when the first drop of oil
falls into the vessel.
3. Measure the oil flow for 5 minutes (Consult the
Technical Data section for the correct rate).
4. Turn the control valve to 1 and repeat the above
procedure.
5. If either of the above input rates are not correct,
the control valve can be adjusted to give the
required rate (see Fig.21). They should only
require slight adjustment and the measurement
procedure described in 2, 3 & 4 above should be
followed to check each adjustment.
6. When the required input rate is achieved,
reassemble the compression fitting ensuring
that there are no leaks and that the burner is
level.