COMMISSIONING
1. Level the stove in all directions using the level-
ling bolts on the stove legs.
2. Remove the flame deflector ring and the flame
spreader from the burner and check that the
ignition probe is within approximately 0.5mm of
the burner base (See Fig.19). Replace the
catalyser and the flame spreader.
Fig.18
Fig.18A
3. Check the control valve rating, see section on
Control Valve Rating below.
4. When the stove reaches its normal operating
temperature (i.e. at maximum setting), adjust the
draught regulator until the desired flame pattern
is achieved.
5. Using the flue sampling point (See Fig.19), check
that the Bacharach smoke number is not greater
than 2. (Hob is removed to access the flue sam-
pling point).
Fig.19
Fig.20
CONTROL VALVE RATING
NOTE:
GREAT CARE SHOULD BE TAKEN TO EN-
SURE THE ACCURACY OF THE FLOW RATE IS
CORRECT, AS IT GREATLY AFFECTS THE
STOVE’S PERFORMANCE.
Apparatus Required:
Collection Vessel
Stopwatch
Graduated Cylinder (capable of measuring
150ml & graduated to the nearest ml)
Small Flat Screwdriver
1. Remove the inlet pipe from the burner.
12
300
300
280
245
Ceramic Logs - A, B, C & D