LOCATION

When choosing a location for this appliance you
must have the following:
A.

Sufficient room for installation and servicing.

B.

Adequate clearance to combustibles 
(see section Clearance to Combustibles).

C.

A satisfactory flue system (See Flue 
Systems).

D.

Fixed fuel supply line and shut off valve 
(See Fuel Supply).

E.

Adequate air supply to support combus
tion (See Ventilation & Combustion Air 
Requirements).

F.

Proper fused power point (See Electrical 
Supply).

G.

Allow for adequate air circulation around 
stove.

H.

Solid floor or base of non-combustible 
material which is capable of supporting 
the total weight of the stove. (See Hearth
Construction).

I.

Position in the area to be heated - central 
locations are usually best.

J.

Avoid installing the stove near door ways, 
windows, walkways and areas with air 
stream passing through.

NOTE: When passing through walls or ceilings 

with the flue system:

K.

Always check for obstructions for example 
electrical fittings, wiring, ducting, plumbing 
and fixed furnishings.

HEARTH CONSTRUCTION

The stove must be installed on a concrete construc-
tion hearth or a non-combustible hearth slab capa-
ble of supporting the weight of the stove and instal-
lation.

Minimum  hearth  size:  =  (697mm)  27.5”  wide,
(732mm) 28.8” deep with the fireplace opening cen-
trally located if applicable.  Avoid running carpets, or
other floor covering under the stove as it is recom-
mended to have the hearth at least (50mm) 2” above
floor level. (See Fig.1).

ELECTRICAL SUPPLY

All wiring external to the appliance must conform to
the  current  B.S.  7671  (UK)  B.S.7462  Safety
Document 635: ETC Part 1 Section 5.4.6 & The
Electricity at Work Regulations.  

The stove requires a 220 V - 240 V 50Hz supply.
Connection of the appliance and any system con-
trols to the mains supply must be through a mould-
ed on plug top which is fitted to the appliance in
accordance  with  EN  60335  and  Consumer
Protection S.I. 1994 No. 1768 Plug and Sockets
(Safety) Regulations 1998.
WARNING:

THIS SUPPLY MUST BE EARTHED

(Refer to B.S. 7430: Code of Practice for Earthing).

IMPORTANT: The appliance plug must be accessi-
ble and so, must not be obstructed and close to the
stove.  To isolate the stove, completely unplug from
the mains socket.  Persons in charge of this stove
should be aware of this socket outlet position.

5

Fig.1

NOTE: Always install in accordance with current
local wiring regulations.

INSTALLATION

The installation shall comply with the following:
B.S. 5410 Part 1 Oil Installations
The Building Regulations:

Part J England, Wales.
Part F Section III Scotland
Part L Northern Ireland
Part J Ireland

The Control of Pollution (Oil) Regulations:
B.S. 7671:  Requirements for Electrical Regulations
Safety Document 635:  The Electricity at Work Regulations.
Safety, Health and Welfare at Work Act for Ireland, England, Wales and Scotland.

Содержание Oisin Oil MK II

Страница 1: ...il MK II Stove INSTALLATION AND OPERATION INSTRUCTIONS To ensure safety satisfaction and reliable service this stove should be installed by a suitably qualified and competent person To be left with en...

Страница 2: ...16 Flue Liner 9 17 Flue Materials 9 18 Sealing 9 19 Flue Height 9 20 Factory Made Insulated Chimneys 9 21 Connections 9 22 Draught Requirements 9 23 Down Draughts 10 24 Ventilation and Combustion Air...

Страница 3: ...vised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled The front door should only be opened if it is necessary to clea...

Страница 4: ...385 412 IMPERIAL inch 21 153 4 173 4 181 4 33 4 5 101 2 221 2 151 6 161 4 4 STOVE WEIGHT 160 lbs 73 kilos NOTE Dimensions stated below may be subject to a slight variation NOTE ALL INSTALLATION WORK...

Страница 5: ...le Avoid running carpets or other floor covering under the stove as it is recom mended to have the hearth at least 50mm 2 above floor level See Fig 1 ELECTRICAL SUPPLY All wiring external to the appli...

Страница 6: ...Screwed joints must only be made with taper threads complying to B S 1740 Part 1 1971 Jointing materials must be of types intended for use with oil fuel Special petroleum resisting compounds and PTFE...

Страница 7: ...OTE Fuel to the appliance should be gravity fed only CLEARANCE TO COMBUSTIBLES See Figs 4 5 6 7 Minimum Clearance to Combustible Materials From the front of stove 1220mm 48 Left side wall looking from...

Страница 8: ...is appliance to a chimney or flue pipe which has previously been used with another fuel the chimney or flue should be thor oughly swept and lined accordingly The combustion products of oil burning app...

Страница 9: ...nto the clear air It must be away from turbulence that may be caused by roof structures other chimney stacks etc The venting position should be 1 meter 3 3 above any obstruction within a 600mm 24 radi...

Страница 10: ...serve the fan s without the air supply passing through the area where the appli ance is installed The provision of an adequate combustion and venti lation air supply is vital for the safe operation of...

Страница 11: ...EN MOVED MUST BE RESEALED WITH A KEROSENE RESISTANT SEALANT 3 Reset the control valve trigger as shown in Fig 16 Once this trigger is reset sudden jolts to the stove can cause it to revert to the off...

Страница 12: ...alve should be adjusted accordingly 10 Each time an adjustment is made to the height of the burner the oil in the central reservoir and in the burner rings should be 13 8 Turn the control knob to 6 fo...

Страница 13: ...pling point on the back casting and measure the draught in the flue way using a manometer or draught gauge see Fig 28 Adjust the counter balance weight anticlockwise until a draught of 0 04 1mm w g is...

Страница 14: ...it down firmly on their grooves and that they do not interfere with the inner wick Replace the inner and outer lids ensuring that the opening in the inner lid is directed towards the front of the stov...

Страница 15: ...g in the stove and turn the control knob to 6 for 12 minutes 2 Press the ignition switch and hold it in until a flame appears This takes between 20 30 seconds 3 Keep the control knob at setting 6 for...

Страница 16: ...ay 9 Check that the burner and oil valve are level 10 With the wicks removed turn the control knob to 6 to fill the burner Check that thecorrect level of oil is present See Commissioning Section Make...

Страница 17: ...above mea sure the minimum feed rate The rate should be approx 4 2cc min 5 If either of the above input rates are not correct the control valve can be adjusted to give the required rate The high fire...

Страница 18: ...19 WIRING DIAGRAM Fig 47...

Страница 19: ...too low in burner Check oil level adjust if long time to light necessary Excessive flame noise Incorrect chimney draught Check joint seals increase height of chimney adjust draught regulator Incorrec...

Отзывы: