INTRODUCTION
To ensure safety, satisfaction and reliable operation, this stove should be installed and commissioned by a
trained and competent person.
IMPORTANT NOTICE
As manufacturers of heating appliances we take every possible care to ensure, as reasonably practicable, that
these appliances are so designed and constructed as to meet the general safety requirements when properly
used, installed and maintained.
Control of substances harmful to health :
* It is the users/installer responsibility to ensure that the necessary personal protective clothing is
worn when handling materials that could be interpreted as being injurious to health
and safety.
See below.
* When handling firebricks, fire cement or fuels use disposable gloves.
* Exercise caution, use disposable masks and gloves when handling glues and sealants. When work
ing with kerosene oil, fibre glass or mineral wool. Avoid contact with skin, eyes, nose and throat,
use disposable protection.
Installation should be carried out in a well ventilated area.
Any alterations to this appliance that are not approved in writing by Waterford Stanley will render the
guarantee void.
This appliance is hot while in operation and retains its heat for a long period of time after use. Children,
aged or infirm persons should be supervised at all times and should not be allowed to touch the hot
working surfaces while in use or until the appliance has thoroughly cooled.
The front door should only be opened if it is necessary to clean the glass. This should only be done
when the stove is cold. The ceramic coal set-up must not be interfered with.
This stove is designed for continuous or intermittent use -When stove is in continuous use it should
be serviced at least every 6 months. If it is not used for extended periods (i.e. during the summer
months) the service period can be extended to 9 - 12 months.
The complete installation must be done in accordance with current Standards and Local Codes. It
should be noted that the requirements and these publications may be superseded during the life of this
manual.
TECHNICAL DATA
Fuel:
Kerosene 28 sec
Mains Current:
220V - 240V, 50Hz, A.C.
Supply Fuse Rating:
5 Amp
Chimney Draught:
0.03” - 0.06” w.g. (1mm - 1.5mm w.g.)
Flue Diameter:
5” (127mm)
Exit Flue Gas Temperature:
120
o
C - 220
o
C
All technical data are taken under laboratory conditions and may vary in use.
3
The manufacturers reserve the right to make alterations to design, materials or construction for manufacturing or other reasons subsequent to publication.
Valve Setting
Oil Consumption
Burner Input
Heat Output
I/h
kW (Btu/h)
kW (Btu/h)
6
0.54
5.13
(17,500)
4.10 (14,000)
5
0.49
4.62
(15,750)
3.70 (12,600)
4
0.43
4.11
(14,000)
3.28 (11,200)
3
0.38
3.59
(12,250)
2.87 ( 9,800)
2
0.32
3.08
(10,500)
2.46 ( 8,400)
1
0.27
2.57
( 8,750)
2.05 ( 7,000)
Содержание Oisin Oil MK II
Страница 18: ...19 WIRING DIAGRAM Fig 47...