Installation & Operating Manual for Argon F650 & F900 – Balanced Flue Gas Stoves
28
Natural Gas & LPG Models
Fitting the Flue to the stove for a Top Exit Configuration (Vertical Flue)
1 - Lift off lid and store in a safe place.
2 - The air inlet flue collar and gasket (150mm diameter) can now be accessed from the top of the fire
(M5 x 16mm cap screws x QTY 4)
3 - Unscrew M5 flange screws (QTY x 6) remove front glass and frame and store in a safe place
4 - Unscrew M5 flange nuts (QTY x 2) from the inside at the top of the fire and carefully remove the heat
shield replace this inner heat shield once you have completed step 8
–
this must be replaced back
into the firebox on completion
5 - The exhaust flue collar & gasket (100mm diameter) can be accessed from the inside top of the fire
(M5 flange nuts QTY x 3)
6 - The exhaust blanking plate & gasket can be accessed from the inside rear of the fire (M5 flange nuts
QTY x 3)
7 - Unscrew M5 cap screws (QTY x 4) and remove back panel and store in a safe place
8 - The air inlet blanking plate and gasket can be accessed from the rear of the fire (M5 cap screws QTY
x4)
9
– Refit the parts as per the following steps in reverse for the above make sure the firebox is air tight on
all of the seals for the 2 x flue collars and front glass
Please note the stove is supplied with the air inlet and exhaust outlet blanking plates fitted to the
rear of the stove. So the 2 x flue collars (supplied loose) would be fitted to the top of the stove for
a vertical flue kit to be installed
Содержание ARGON F650
Страница 13: ...GB IE version 13...
Страница 15: ...GB IE version 15 Remote Control Operating Instructions continued...
Страница 17: ...GB IE version 17 Remote Control Operating Instructions continued...
Страница 55: ...GB IE version 55 Appendix 1 Fault Finding Chart...
Страница 56: ...Installation Operating Manual for Argon F650 F900 Balanced Flue Gas Stoves 56 Natural Gas LPG Models...
Страница 57: ...GB IE version 57...
Страница 61: ...GB IE version 61 ARGON F650 Balanced Flue Gas LPG Waterford Stanley ARGON F650 Balanced Fuel Gas LPG 4 4...
Страница 63: ...GB IE version 63 ARGON F900 Balanced Flue Gas LPG Waterford Stanley ARGON F900 Balanced Fuel Gas LPG 6 3...